Adairsville, Bartow County

Adairsville Hotel DBA Days Inn

500 GEORGIA NORTH CIR ADAIRSVILLE, GA 30103

Pool
Latest score
95
Jul 8, 2025
City
Adairsville
County
Bartow
Inspections
4

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jul 8, 2025

Routine

Score: 951 violation

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed combined chlorine total of 1.12ppm. CA: Combined chlorine level should be less than 0.4ppm difference from free chlorine level. Adjust chemical levels downward

Jun 3, 2025

Re-inspection

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed Cyanuric acid levels reading at 180ppm. CA: informed PIC levels must not exceed 90ppm.

May 19, 2025

Permit/Opening

Score: 718 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone not working. CA: informed PIC

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Observed free chlorine reading at 0.30ppm. Chlorine levels must be between 2-10ppm. CA: informed PIC

8 - chemical feeder operational and approved

Regulation: 511-3-5-.16(2)(a) - (a) every pool and spa shall be required to have at least one unit of disinfectant agent equipment that introduces the agent through the circulation system in compliance with this rule

15 ptsCorrected: NoRepeat: No

Observed chlorine being introduced through a floating basket and through skimmer baskets. CA: informed CPO

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed flow meter only reading at 50gpm, not meeting the turnover rate of 6 hours. CA: informed PIC

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed Cyanuric acid levels reading at 162ppm. CA: informed PIC levels must not exceed 90ppm.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed pool ladder was loose and did not have rubber backings. CA: informed PIC

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Observed no pool risks sign. CA: informed PIC

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed pump room and chemical storage rooms doors left unlocked with no CPO present. Informed PIC the doors should be locked at all times for safety.

Jun 26, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.