CARTERSVILLE, Bartow County

BRAMBLEWOOD

10 BRAMBLEWOOD TRL CARTERSVILLE, GA 30120

Pool
Latest score
95
May 19, 2026
City
CARTERSVILLE
County
Bartow
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 19, 2026

Permit/Opening

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter not sized appropriately to give accurate turnover rate. Pumps do state turnover rate but we require an operational flow meter as well.

Jul 9, 2025

Re-inspection

Score: 951 violation

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed inadequate flow rate. CA: flow rate must be at least 150gpm to meet required turnover rate.

Jul 7, 2025

Routine

Score: 715 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine levels below minimum allowed. CA: Chlorine level must be between 2-10ppm.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH below minimum allowed. CA: pH level must be between 7.2-7.8.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: Yes

Observed flow meter broken/not functional. CA: Pool must have a functioning flow meter to calculate turnover rate.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

Observed flow meter broken/not functional. CA: Pool must have a functioning flow meter to calculate turnover rate.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed cyanuric acid levels above the maximum allowed. CA: cyanuric acid levels may not exceed 90ppm.

May 22, 2025

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed pool not turning over at appropriate rate according to flow meter. Turnover rate should be 8 hours (based on pool construction existing prior to state rules). Flow meter should read 150gpm or higher

May 24, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 5, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.