CARTERSVILLE, Bartow County

LIBERTY CROSSING

11 ALLEGIANCE CT CARTERSVILLE, GA 30121

Pool
Latest score
100
Apr 20, 2026
City
CARTERSVILLE
County
Bartow
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 20, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 26, 2025

Re-inspection

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: Yes

Observed cyanuric acid exceeding maximum amount allowed. CA: Cyanuric acid levels may not exceed 90ppm.

Jun 25, 2025

Routine

Score: 715 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone not operational. CA: Pool must have an operable emergency phone.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH below minimum allowed. CA: the pools pH level must be between 7.2-7.8.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed flow meter not working. CA: pool must have a working flow meter to calculate correct turnover rate.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter that is in need of repair. CA: Pool must have a working flow meter to calculate correct turnover rate.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: Yes

Observed cyanuric acid exceeding maximum amount allowed. CA: Cyanuric acid levels may not exceed 90ppm.

Apr 25, 2025

Permit/Opening

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: Yes

Observed cyanuric acid exceeding maximum amount allowed. CA: Notified CPO. Cyanuric acid should not exceed no more than 90ppm.

Apr 18, 2024

Permit/Opening

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed cyanuric acid exceeding maximum amount allowed. CA: Notified PIC. Cyanuric acid should not exceed no more than 90ppm.

Aug 18, 2023

Routine

Score: 932 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter that is in need of repair. CA: Notified CPO

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed loose hand railing near the 5ft deep side of the pool. CA: Notified PIC. CPO will have railing tightened.