Macon, Bibb County

Forest Park MHP

100 WESTWOOD CIR MACON, GA 31206

Pool
Latest score
79
Jun 1, 2026
City
Macon
County
Bibb
Inspections
3

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 1, 2026

Permit/Opening

Score: 794 violations

3 - compliant drain covers secure, present and no cracks

Regulation: .10(5) - compliant drain cover

15 ptsCorrected: NoRepeat: No

Observed main drain cover missing. Was informed maintenance was waiting for pool to clear up to place cover.

.10(5) - Compliant Drain Cover (5) Entrapment Avoidance. If the suction outlet system, such as a filtration system,booster system, automatic cleaning system, or solar system, has a single suction outlet or multiple suction outlets which can be isolated, each suction outlet shall protect against user entrapment by installing a cover/grate that complies with ANSIAPSP- 7 Standard for Suction Entrapment Avoidance in Swimming Pools, Wading Pools, Spas, Hot Tubs,and Catch Basins or successor standard and as many of the following as necessary:

Corrective action: Discussed with maintenance and manager to have main drain installed as soon as possible.

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Observed calcium hardness levels at 113.

511-3-5-.23(5)(a) - (a) During operation, disinfectant levels are less than the minimum level specified in DPH Rule 511-3-5-.17. If the level of the disinfectant used is not specified in DPH Rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin (a) During operation, disinfectant levels are less than the minimum level specified in DPH Rule 511-3-5-.17. If the level of the disinfectant used is not specified in DPH Rule 511-3-5-.17, the disinfectant must be approved and kept at levels determined necessary by the health authority.

Corrective action: Discussed with PIC to have chemicals rebalanced.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed weirs missing from the skimmers.

511-3-5-.11(3)(d) - (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches. (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

Corrective action: Discussed with PIC to have weirs installed on all the skimmers.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed no peak occupancy noted within the pool not pool hours.

511-3-5-.18(13)(c) - (c) A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy. (c) A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

Corrective action: Discussed with maintenance to add the pool hours and peak occupancy

Jul 24, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 7, 2023

Permit/Opening

Score: 883 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed the facility's combined chlorine reading at .48ppm.1) Disinfectant Levels (a) Free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use. Facility is to adjust chemical concentration and re-test as it should not exceed .40 ppm.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed facility's flow meter not providing accurate flow as it doesn't allow for maximum flow. b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

Facility is to install flow meter with enough ppm; facility has one but it does not work.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed facility's need to post the peak occupancy of bathers and operation hours on the entrance gates. (c) A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy. FFacility is to post information.