May 8, 2026
Permit/Opening
3288 CLAIRMONT AVE MACON, GA 31204
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Permit/Opening
Permit/Opening
Regulation: .17((1)(c) - proper disinfectant level
EHS measured a free chlorine level 0f 0.21. For pools using a stabilized chlorine product Free chlorine should be 2.0. Increase automatic feeder to increase chlorine in pool.
Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.
EHS observed combined chlorine 1.18. Combined chlorine should be 0.4 ppm or less. Will need to adjust chlorine feeder.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
EHS observed flow meter on right pump not functioning. Flow meter shall be installed and have the appropriate range. Replace flow meter.
Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.
EHS observed no diving tile that has symbol and writing. Letters of No diving shall be 4" tall. Need to stencil and/or order tiles for no diving.
Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.
EHS observed pressure gauge on right pump not functioning. Pressure gauge shall be functioning to indicate system condition. Replace pressure gauge.
EHS observed no drinking fountain available at pool. Drinking fountain shall be available at the pool site. Install drinking fountain.