St. Marys, Camden County

Colerain Oaks Pool #2

306 RYAN DR SAINT MARYS, GA 31558

Pool
Latest score
100
May 1, 2026
City
St. Marys
County
Camden
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 1, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Oct 1, 2025

Routine

Score: 852 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

At time of inspection, the pH registered at 8.4 (pH must be within range of 7.2-7.8). The pool is being covered today and will remain closed until next season.

10 - pump: approved, maintained and operating

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

At time of inspection, the pump is shut off, due to a leak. The CPO is working on replacing the pump housing (it has been ordered). The pool is being covered today and will remain closed until next season.

Apr 29, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Oct 25, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 24, 2024

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: YesRepeat: No

At beginning of inspection, the emergency phone was not operating properly (there was a dial tone, but the phone would not dial - the phone has no buttons and is designed to dial 911 when the receiver is picked up). COS: Management installed a spare phone and it is capable of dialing 911 (tested to confirm). Operating permit issued.