St. Marys, Camden County

Cumberland Harbour Adult Pool

123 CLUB HOUSE CIR SAINT MARYS, GA 31558

Pool
Latest score
96
May 6, 2026
City
St. Marys
County
Camden
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 6, 2026

Permit/Opening

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid (CYA) level registered at 95 ppm (CYA must be 90 ppm or less). CPO has reduced CYA considerably since last inspection, and will continue to gradually drain and refill.

Oct 23, 2025

Routine

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid (CYA) level registered at 247 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water, until CYA is below 90 ppm.

May 28, 2025

Permit/Opening

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid level registered at 212 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water.

Sep 23, 2024

Routine

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: YesRepeat: No

At time of inspection, the emergency phone was not operational. CPO contacted management and the phone was fixed during the course of the inspection.

Apr 23, 2024

Permit/Opening

Score: 912 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

At time of inspection, combined chlorine was high (combined chlorine registered at 0.65 ppm - it must be less than 0.40 ppm). CPO will drain water some and add fresh water to lower combined chlorine.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, cyanuric acid was high (CYA registered as "Hi" on test kit - level is beyond range of test kit). CPO will drain some and add fresh water to lower cyanuric acid concentration.

Jul 26, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.