St. Marys, Camden County

Winding River Wading Pool

102 MEANDERING WAY SAINT MARYS, GA 31558

Pool
Latest score
96
Mar 20, 2026
City
St. Marys
County
Camden
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Mar 20, 2026

Permit/Opening

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid (CYA) registered at 188 ppm (CYA must be 90 ppm or less). CPO states the wading pool will be drained and refilled.

Sep 9, 2025

Routine

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid (CYA) level registered at 170 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water. CPO also states less tabs are being used now and liquid chlorine is being used.

Mar 28, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Oct 16, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 16, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 13, 2023

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: YesRepeat: No

At time of inspection, the emergency phone is not operational. PIC contacted phone company and will contact EHS once the phone is operational. PIC states she will contact EHS to come verify that the emergency phone is operational. PIC placed a spare hardwired phone on the porch and ran a line from the phone jack inside as a temporary solution, until the emergency phone is fixed.