St. Marys, Camden County

Hickory Plantation Apartments

900 DILWORTH ST SAINT MARYS, GA 31558

Pool
Latest score
100
Apr 24, 2026
City
St. Marys
County
Camden
Inspections
11

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 24, 2026

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Apr 23, 2026

Re-inspection

Score: 851 violation

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: Yes

At time of inspection, the free chlorine level registered at 0.16 ppm (FCL must be between 2.00 - 10.00 ppm). CPO will adjust. The pool must remain closed, until it has passed re-inspection.

Apr 22, 2026

Re-inspection

Score: 851 violation

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

At time of inspection, the free chlorine level registered at 0.18 ppm (FCL must be between 2.00 - 10.00 ppm). CPO will adjust. The pool must remain closed, until it has passed re-inspection.

Apr 21, 2026

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

At time of inspection, the emergency phone is not operational (static is heard and dispatcher stated no call came through). The pool must be closed and remain closed, until the pool has passed re-inspection.

Oct 9, 2025

Routine

Score: 981 violation

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

At time of inspection, the peak occupancy / hours of operation sign is missing. CPO will order the sign and install ASAP.

Apr 17, 2025

Permit/Opening

Score: 942 violations

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid level registered at 173 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

At time of inspection, the peak occupancy / hours of operation sign is missing. CPO will order a sign and install it ASAP.

Nov 19, 2024

Routine

Score: 981 violation

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

At time of inspection, the peak occupancy sign is missing. CPO will acquire the sign and install it ASAP.

May 24, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

May 1, 2024

Permit/Opening

Score: 853 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

At time of inspection, the emergency phone was not functioning properly (certain buttons do not work - the "1" and the "9" are two of the buttons that do not work). Property manager contacted maintenance to troubleshoot the phone.

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

At time of inspection, free chlorine registered at 1.38 ppm (free chlorine must be at least 2.00 ppm for this pool). CPO will adjust feeder to increase chlorine concentration.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

At time of inspection, the rope is missing from the ring buoy. CPO states he has a rope and will attach it.

Jun 9, 2023

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jun 9, 2023

Re-inspection

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: Yes

At time of inspection, emergency phone is still not operating properly (some buttons - including the "9" - are not functional. PIC (Person-in-Charge) contacted technician and will contact EH Office, once the phone is fully functional. At that point, a re-inspection can be scheduled.