Carrollton, Carroll County

Mayfair At Carrollton

318 COLUMBIA DR CARROLLTON, GA 30117

Pool
Latest score
98
Apr 2, 2026
City
Carrollton
County
Carroll
Inspections
11

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 2, 2026

Permit/Opening

Score: 981 violation

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Fully secure ladder on left side

Jul 25, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jul 23, 2025

Routine

Score: 851 violation

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

pH measured at 7.0 at time of inspection

May 21, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 21, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Aug 12, 2024

Re-inspection

Score: 852 violations

4 - water clarity: main drains clearly visible

Regulation: 511-3-5-.23(5)(d) - (d) the water turbidity is such that the suction outlet/main drain cover or a standard white marker tile on the bottom of the deepest portion of the pool cannot be seen.

15 ptsCorrected: NoRepeat: No

Observed cloudy water at time of inspection

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

pH measured at 7.0 at time of inspection

Aug 8, 2024

Routine

Score: 852 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Free chlorine measured at 0 ppm at time of inspection

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

pH measured at 7.0 at time of inspection

May 16, 2024

Permit/Opening

Score: 961 violation

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

CPO must be on site for opening inspection and must show CPO credentials.

May 8, 2024

Permit/Opening

Score: 764 violations

8 - chemical feeder operational and approved

Regulation: .16(2)(b) - chemical feeder

15 ptsCorrected: NoRepeat: No

Observed chlorine tables inside skimmer baskets; chemical feeder with no chlorine tablets inside./Chemical feeder must be working properly and chemicals must be fed through chemical feeder

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

Observed chlorine tables inside skimmer baskets./corrected

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.09(9)(b) - (b) the pressure gauge shall be installed downstream from the pump, on the face piping ahead of the filter or on top of the filter in the area of greatest filter pressure.

4 ptsCorrected: NoRepeat: No

Unable to read pressure gauge

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

Mark and identify pipes with directional flow and arrows.

Aug 17, 2023

Routine

Score: 972 violations

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Ladders missing rubber caps on end./Replace.

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

Mark and identify pipes with directional flow and arrows.

May 25, 2023

Permit/Opening

Score: 972 violations

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Ladders missing rubber caps on end./Replace.

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

Mark and identify pipes with directional flow and arrows.