May 23, 2024
Permit/Opening
385 N GODLEY STATION POOLER, GA 31322
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
Observed pH at 7.0.
RCA: pH shall be between 7.2-7.8
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter to be non-operational at the time of inspection. RCA: A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.
Observed calcium hardness to be 90ppm. RCA: Calcium hardness should be between 150ppm-1000ppm at all times.
Permit/Opening
Regulation: .17((1)(c) - proper disinfectant level
Observed free chlorine level to be 20ppm at time of inspection. RCA: Chlorine levels must be maintained between 2ppm-10ppm at all times.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter to be non-operational at the time of inspection. RCA: A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
Observed facility to not have a copy of the certified pool operator certificate in possession at the time of inspection. RCA: The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority.
Observed calcium hardness to be 115ppm. RCA: Calcium hardness should be between 150ppm-1000ppm at all times.
Permit/Opening
Observed calcium hardness at 80ppm. CA: Calcium hardness should be between 150ppm-1000ppm at all times.