Pooler, Chatham County

The Carlyle At Godley Station

385 N GODLEY STATION POOLER, GA 31322

Pool
Latest score
100
May 23, 2024
City
Pooler
County
Chatham
Inspections
4

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 23, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 17, 2024

Permit/Opening

Score: 793 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pH at 7.0.

RCA: pH shall be between 7.2-7.8

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter to be non-operational at the time of inspection. RCA: A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed calcium hardness to be 90ppm. RCA: Calcium hardness should be between 150ppm-1000ppm at all times.

May 16, 2024

Permit/Opening

Score: 754 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed free chlorine level to be 20ppm at time of inspection. RCA: Chlorine levels must be maintained between 2ppm-10ppm at all times.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter to be non-operational at the time of inspection. RCA: A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

Observed facility to not have a copy of the certified pool operator certificate in possession at the time of inspection. RCA: The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority.

37 - other violations of the chapter

1 ptsCorrected: YesRepeat: Yes

Observed calcium hardness to be 115ppm. RCA: Calcium hardness should be between 150ppm-1000ppm at all times.

Jun 27, 2023

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed calcium hardness at 80ppm. CA: Calcium hardness should be between 150ppm-1000ppm at all times.