Savannah, Chatham County

Perry Lane Hotel

256 E PERRY ST SAVANNAH, GA 31401

Pool
Latest score
100
Jun 4, 2026
City
Savannah
County
Chatham
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 4, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Oct 1, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Mar 27, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 31, 2024

Permit/Opening

Score: 942 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed bobber stuck in the bottom of the flow meter and unable to show accurate reading of flow.

RCA: PIC shall have bobber dislodged or have the flow meter replaced if needed. A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed total alkalinity reading of 290 ppm.

RCA: CPO shall make appropriate adjustments to lower total alkalinity within range. Total alkalinity shall be at a minimum of 60ppm; ideally 60-100ppm; at a maximum of 180ppm.

May 30, 2024

Permit/Opening

Score: 844 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone on the pool deck to be connecting to the lobby emergency telephone and deck phone unable to connect to operator.

RCA: An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available.

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed free chlorine levels at 0.5 ppm.

RCA: Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH levels below 7.0.

RCA: pH shall levels shall be within 7.2 - 7.8. During operation, the pH is less than the minimum or more than the maximum levels allowed in DPH Rule 511-3-5-.l7.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed total alkalinity of 22ppm.

RCA: Total alkalinity shall be at least 60 ppm.

Jun 27, 2023

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed total alkalinity of 40ppm.

RCA: Total alkalinity shall be at least 60 ppm.