Jun 3, 2026
Permit/Opening
412 W BAY ST SAVANNAH, GA 31401
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Permit/Opening
Re-inspection
Re-inspection
Regulation: .17((1)(c) - proper disinfectant level
Observed free chlorine at 1.2ppm. Maintain free chlorine between 2-10ppm.
Observed pH of 8.0 Maintain pH level between 7.2-7.8ppm
Routine
Regulation: .17((1)(c) - proper disinfectant level
Observed free chlorine concentration at 1.77 and 1.20 in consequent readings. Maintain free chlorine between 2-10 ppm.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Skimmers does contain weirs. Weirs need to be installed as soon as possible.
Observed pool alkalinity at 192 ppm.
RCA: Maintain alkalinity between 60-180 ppm.
Observed calcium hardness at 88 ppm.
Maintain calcium hardness between 150- 1000 ppm
Permit/Opening
Observed pH of 6.7.
RCA: Maintain pH level of 7.2-7.8.
Observed chemical feeder not working. PIC is putting chlorine tablets in skimmer baskets.
CA: ECOlab coming back by end of the week to replace chlorinator. EH specialist will be back to verify.
RCA: Contact ECO lab to maintenance chlorinator so that chlorine can automatically filter through the pool.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter not operating.
RCA: 511-3-5-.07(4)(b) - (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
No CPO certificate on site during time of inspection.
RCA: 511-3-5-.22(2) - (2) The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority. (2) The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority.
Observed alkalinity level of 60.
RCA: Maintain alkalinity level between 60-180.
Observed calcium hardness of 140.
RCA: Maintain calcium hardness level between 150-1000ppm.