Jun 23, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Mar 12, 2024

Permit/Opening

Score: 992 violations

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

Observed calcium hardness to be 75 ppm. RCA: Calcium hardness shall be between 150-1000ppm.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed alkalinity to be too high 238. RCAL Maintain between 60-180ppm

Aug 21, 2023

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

Observed calcium hardness to be 92 ppm. RCA: Calcium hardness shall be between 150-1000ppm.

Jul 28, 2023

Routine

Score: 893 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter not operational. CA:CPO will replace flow meter. RCA: A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Observed facility to not be testing at least once a day. CPO was able to provide a log with their routine testing twice a weeks since the opening inspection. RCA: The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. An in-line sampling port may be used for water held in reservoirs. Daily record logs shall be done and kept on sight.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed calcium hardness to be 90 ppm. RCA: Calcium hardness shall be between 150-1000ppm.