Apr 15, 2026
Permit/Opening
200 CREEK VIEW DR ACWORTH, GA 30102
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Flow meter not working properly. Repair/replace flow meter
Permit/Opening
Permit/Opening
pH high. Keep 7.2-7.8
Observed turn over rate at 88 gpm and should be at min 105 gpm.
Routine
Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat
Observed turn over rate at 70 gpm and should be at min 105 gpm. Backwashing is recommended to adjust flow rate
Permit/Opening
Routine
Permit/Opening