May 22, 2026
Permit/Opening
37 - other violations of the chapter
Must provide baby changing station in both the rest rooms. Need action before next routine inspection.
230 BIRCH BEND DR ALPHARETTA, GA 30004
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Must provide baby changing station in both the rest rooms. Need action before next routine inspection.
Routine
Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.
Replace the broken escutcheon plate on the hand rail in the pool.
Must provide baby changing station in both the rest rooms.
Permit/Opening
Must provide baby changing station in both the rest rooms.
Re-inspection
Routine
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Emergency phone not functioning. The emergency phone shall be capable of connecting to 911.
Permit/Opening
Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
Post Sign With pool occupancy and pool hours
511-3-5-.18(13)(c) - (c) A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy. (c) A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
Routine
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Cyanuric acid is >90 ppm. Must be below 90 ppm.
Permit/Opening
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Weir (skimmer door) missing on one of the skimmer baskets. Must replace
Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.
Floatation valve missing. This covers the skimmer equalizer line. Must replace.