ALPHARETTA, Cherokee County

Forest Glen

230 BIRCH BEND DR ALPHARETTA, GA 30004

Pool
Latest score
99
May 22, 2026
City
ALPHARETTA
County
Cherokee
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 22, 2026

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Must provide baby changing station in both the rest rooms. Need action before next routine inspection.

Aug 14, 2025

Routine

Score: 972 violations

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Replace the broken escutcheon plate on the hand rail in the pool.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Must provide baby changing station in both the rest rooms.

Jun 20, 2025

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Must provide baby changing station in both the rest rooms.

Aug 7, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Aug 6, 2024

Routine

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone not functioning. The emergency phone shall be capable of connecting to 911.

May 23, 2024

Permit/Opening

Score: 981 violation

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Post Sign With pool occupancy and pool hours

511-3-5-.18(13)(c) - (c) A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy. (c) A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

Aug 28, 2023

Routine

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Cyanuric acid is >90 ppm. Must be below 90 ppm.

May 26, 2023

Permit/Opening

Score: 962 violations

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Weir (skimmer door) missing on one of the skimmer baskets. Must replace

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

Floatation valve missing. This covers the skimmer equalizer line. Must replace.