Canton, Cherokee County

Heritage at Riverstone

103 HERITAGE DR CANTON, GA 30114

Pool
Latest score
100
Jun 5, 2026
City
Canton
County
Cherokee
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 5, 2026

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jul 21, 2025

Routine

Score: 992 violations

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Drainage issue on pool deck causing standing water. Deck must be properly sloped to drain water away

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Emergency phone must say pool phone in address.

Jul 9, 2025

Routine

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Water fountains not functional at time of inspection. - Repair water fountains.

May 31, 2024

Routine

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Must fix the water fountain. Must provide baby changing station in each rest room.

Jul 3, 2023

Re-inspection

Score: 912 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: Yes

Flow meter is reading around 80 GPM. The turnover rate for this pool is 119 GPM.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed cyanuric acid exceeding maximum (>100 ppm). Must be below 90 ppm.

Jun 30, 2023

Re-inspection

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

911 does not have record of pool address. Must fix prior to re-opening.

Jun 28, 2023

Routine

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone is not working. Must fix prior to re-opening.