May 22, 2026
Permit/Opening
462 SUMMIT VIEW LN CANTON, GA 30114
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
Front pool gate is not self-latching and back pool gate (near pump room) is not opening to exit. Must fix .
Re-inspection
Routine
Regulation: .17((1)(c) - proper disinfectant level
Free chlorine measured at 1.0 ppm. Pool uses stabilized chlorine—minimum required is 2.0 ppm per DPH Rule 511-3-5-.17(1)(c).
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
Low pH reading of 7.0 during operation. Must be maintained between 7.2–7.8 per DPH Rule 511-3-5-.17.
Regulation: 511-3-5-.09(2) - (2) strainer or screen. with all pressure filter systems, a cleanable strainer or screen shall be provided upstream of the circulation pumps to remove solids and debris such as hair and lint.
Pump strainer basket not cleanable due to debris buildup. Must be kept clean to ensure proper flow and filtration per DPH rule.
Permit/Opening
Permit/Opening
Re-inspection
Re-inspection
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Observed the emergency phone not working. The emergency phone needs to be operable at all times.
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed a pH less than 7.0. The pH must be between 7.2-7.8.
Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type
Observed a turnover rate of 160 gpm. The required turnover rate for this pool is 220 gpm.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Observed one skimmer basket missing a weir. All skimmer baskets must have weirs.
Routine
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Observed the emergency phone not working. The emergency phone needs to be operable at all times.
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed a pH less than 7.0. The pH must be between 7.2-7.8.
Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type
Observed a turnover rate of 170 gpm. The required turnover rate for this pool is 220 gpm.
Observed one skimmer basket missing a weir. All skimmer baskets must have weirs.