Canton, Cherokee County

Fairfield Inn & Suites/ Town Place Suites

120 REINHARDT COLLEGE CANTON, GA 30114

Pool
Latest score
76
May 28, 2026
City
Canton
County
Cherokee
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 28, 2026

Re-inspection

Score: 961 violation

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

Install effluent pressure gauge on the return line.

May 28, 2026

Permit/Opening

Score: 764 violations

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed free chlorine at 13ppm. Must be between 1 and 10ppm.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH less than 7.2 Must be between 7.2 and 7.8

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed flow rate at 50gpm. Must be at least 64gpm.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed cyanuric acid greater than 100ppm. Must be below 90ppm. Ideal-30 to 50ppm.

Jul 7, 2025

Routine

Score: 951 violation

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Chemicals must be checked twice a day and make necessary adjustments. Logs must be maintained.

Apr 4, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 24, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Apr 18, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 27, 2023

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Aug 23, 2023

Routine

Score: 851 violation

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Chlorine is high, at 15.5 ppm.