May 13, 2026
Permit/Opening
1008 MIDDLEBROOKE DR CANTON, GA 30115
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Cyanuric acid is greater than 90ppm. Must be below 90ppm. ideal- 30-50ppm
Permit/Opening
Must provide baby changing station in both the restrooms.
Re-inspection
No onsite daily logs for chemical testing - Trained operator/HOA/Property Management shall test the pools twice daily for pH and free Chlorine, weekly for alkalinity, monthly for hardness, and twice monthly for cyanuric acid. 511-3-5-.22(9) - (9) Water Testing Frequency. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. An in-line sampling port may be used for water held in reservoirs. The water quality testing frequency shal (9) Water Testing Frequency. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. An in-line sampling port may be used for water held in reservoirs. The water quality testing frequency shall be as follows:
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Missing weirs on pool x4 - Replace missing weirs
511-3-5-.11(3)(d) - (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches. (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Fountain is not operable and needs to be cleaned - Repair and clean
511-3-5-.18(16) Specific Safety Features and Markers. (16) At least one drinking fountain shall be provided and available to users at the pool site.
No diaper changing stations - Install diaper changing stations in both restrooms. 511-3-5-.19 Dressing Facilities and Sanitary Facilities. (m) Facilities shall provide a minimum of one diaper changing station in the male and female bathroom or dressing area. New Violation
Pump room is in poor condition - Make arrangements for repair prior to next pool season New Violation.
Routine
Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin
Free Chlorine is at 0ppm - Maintain between 2-10ppm
511-3-5-.23(5)(a) - (a) During operation, disinfectant levels are less than the minimum level specified in DPH Rule 511-3-5-.17. If the level of the disinfectant used is not specified in DPH Rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin (a) During operation, disinfectant levels are less than the minimum level specified in DPH Rule 511-3-5-.17. If the level of the disinfectant used is not specified in DPH Rule 511-3-5-.17, the disinfectant must be approved and kept at levels determined necessary by the health authority.
Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
No onsite daily logs for chemical testing - Trained operator/HOA/Property Management shall test the pools twice daily for pH and free Chlorine, weekly for alkalinity, monthly for hardness, and twice monthly for cyanuric acid. 511-3-5-.22(9) - (9) Water Testing Frequency. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. An in-line sampling port may be used for water held in reservoirs. The water quality testing frequency shal (9) Water Testing Frequency. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. An in-line sampling port may be used for water held in reservoirs. The water quality testing frequency shall be as follows:
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Missing weirs on pool x4 - Replace missing weirs
511-3-5-.11(3)(d) - (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches. (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Fountain is not operable and needs to be cleaned - Repair and clean
511-3-5-.18(16) Specific Safety Features and Markers. (16) At least one drinking fountain shall be provided and available to users at the pool site.
No diaper changing stations - Install diaper changing stations in both restrooms.
511-3-5-.19 Dressing Facilities and Sanitary Facilities. (m) Facilities shall provide a minimum of one diaper changing station in the male and female bathroom or dressing area.
Pump room is in poor condition - Make arrangements for repair prior to next pool season
Permit/Opening
Re-inspection
Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
pH and chlorine must be checked twice a day. Logs must be maintained onsite.
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Cyanuric acid is greater than 90ppm. Must be below 90ppm. ideal- 30-50ppm
Routine
Regulation: .17((1)(c) - proper disinfectant level
Free chlorine is at 0 ppm. Must be between 2-10 ppm.
Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type
Flow meter is reading around 150 gpm. The turnover rate for this pool is 226 gpm.
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Cyanuric acid is >90 ppm. Must be <90 ppm.
Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:
There are no current CPO logs.
Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.
Inspection report not posted in public view.