WOODSTOCK, Cherokee County

Willow Tree

1324 WILLOW TREE DR WOODSTOCK, GA 30189

Pool
Latest score
95
Apr 13, 2026
City
WOODSTOCK
County
Cherokee
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 13, 2026

Permit/Opening

Score: 952 violations

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

Must install effluent pressure gauge.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Must provide baby changing station in men's rest room.

Jul 29, 2025

Routine

Score: 863 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter reading ~ 90 GPM. Must ~ 125 GPM. Replace/move the flowmeter to a different location (straight pipe- not close to the elbows) or replace so that the flow is 125 GPM.

511-3-5-.07(4)(b) - (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Daily chemical readings not available for review. Keep written log of daily chemical readings in the pump room.

511-3-5-.22(12) - (12) A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet. (12) A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Cyanuric acid greater than 100 ppm. Corrective action: Must be less than 90 ppm, ideal 50-30 ppm.

511-3-5-.17(4) - (4) Stabilizer (if used) Cyanuric acid,ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: - May reduce chlorine efficacy Too Low: - Chlorine Residual rapidly destroyed by sunlight Note: Stabilizer is not needed in indoor or br (4) Stabilizer (if used) Cyanuric acid,ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: - May reduce chlorine efficacy Too Low: - Chlorine Residual rapidly destroyed by sunlight Note: Stabilizer is not needed in indoor or brominated pools and spas.

Apr 15, 2025

Permit/Opening

Score: 903 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter reading at 70gpm. Must be 125gpm. Must move the flowmeter to a different location (straight pipe- not close to the elbows) or replace so that the flow is 125gpm.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

Must install effluent pressure gauge.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Must provide baby changing station in both the rest rooms.

Jul 24, 2024

Routine

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Cyanuric acid is greater than 100ppm. Must be below 90ppm.

May 2, 2024

Permit/Opening

Score: 923 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Turn over rate must be 125 gpm. Flow meter reading at 100gpm.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Must post the peak occupancy in 4 inch letters and the hours of operation.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Must provide baby changing station in both the rest rooms.

Aug 16, 2023

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Aug 9, 2023

Routine

Score: 802 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone not working.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter reading at 70gpm. Must be 125gpm.