COLLEGE PARK, Clayton County

Hub @ 934

934 GARDEN WALK BLVD COLLEGE PARK, GA 30349

Pool
Latest score
80
Jun 9, 2026
City
COLLEGE PARK
County
Clayton
Inspections
3

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 9, 2026

Permit/Opening

Score: 802 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: YesRepeat: No

Observed ph reading below 7.2. COS Now at 7.6

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed pool not meeting adequate turnover.

Jul 28, 2025

Permit/Opening

Score: 6710 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.18(11)(a) - (11) barriers. all outdoor swimming pools and spas shall be enclosed by a barrier to prevent entry to the pool area when the pool is closed. (a) the top of the barrier shall be at least forty eight inches above grade maesured on the side of the bar

15 ptsCorrected: NoRepeat: No

Large gap present under fence near gate area. Fill dirt may be used to reduce size of gap. Gap shall be reduced to prevent unauthorized entry to pool. Pool to remain closed until cleared and satisfactory score reached

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Gate to pool does not latch/ lock. Gate shall be self closing and self latching. Pool to remain closed until satisfactory score reached

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

PH observed too low 7.0. PH shall be 7.2-7.8. Pool closed until satisfactory score reached and PH is within proper range

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(a) - (a) a light, strong pole not less than twelve feet long including body hook.

15 ptsCorrected: NoRepeat: No

No life saving equipment( Shepard hook, safety float at pool side) They were stored in the chemical room. Shall be stored in proper area.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Turnover rate can not be verified due to flow meter not working.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter observed not working. Shall be repaired/ or placed.

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(c )1.ii. - (ii) the fitting shall not constitute a hazard to the user.

4 ptsCorrected: NoRepeat: No

Missing 1 return inlet cover. Cover shall be replaced.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

No required signs were observed. All required signs shall be posted

30 - deck/rinse shower maintained

Regulation: 511-3-5-.18(17) - (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.

1 ptsCorrected: NoRepeat: No

Deck shower not functioning properly( very low pressure).

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Pool shell has rust stains and etching in multiple areas. Pictures were taken- Pool will have to be resurfaced prior to 2026 pool season in order to obtain 2026 pool permit

Aug 2, 2023

Permit/Opening

Score: 786 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.18(11)(a) - (11) barriers. all outdoor swimming pools and spas shall be enclosed by a barrier to prevent entry to the pool area when the pool is closed. (a) the top of the barrier shall be at least forty eight inches above grade maesured on the side of the bar

15 ptsCorrected: NoRepeat: No

Observed section of gates lower then the required height of 48 inches, observed several areas were the base of gate is more then 4 inches from the ground.

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed the gate not latching

10 - pump: approved, maintained and operating

Regulation: 511-3-5-.09(1) - (1) sizing. a pump and motor shall be provided for circulation of the pool and spa water. performance of all pumps shall meet or exceed the conditions of flow required for filtering and cleaning (if applicable) the filters against the total dynamic h

15 ptsCorrected: NoRepeat: No

Pump flow can not be verified as being sufficient to meet the required flow of 149 gpm.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.23(5)(h) - (h) absence of required lifesaving equipment on the deck or an emergency phone;

15 ptsCorrected: NoRepeat: No

Life saving equipment is not all present. Life buoy is damaged and will need to be replaced.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Turnover rate observed and does not meet 6hrs. 149gpm rate is needed and the flow meter observed at 58gpm.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

No peak occupancy sign observed. Must be present