JONESBORO, Clayton County

Southlake Cove Apartments

7509 JONESBORO RD JONESBORO, GA 30236

Pool
Latest score
100
Jun 18, 2025
City
JONESBORO
County
Clayton
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 18, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 3, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jul 2, 2024

Re-inspection

Score: 851 violation

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: Yes

Gate not self-latch/ self-closing lower level.

Jul 1, 2024

Permit/Opening

Score: 755 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Gate observed self-close/self-latch. Advised to have gate repaired.

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: YesRepeat: No

Upon arrival Cl @ 1ppm. COS-read 2 ppm.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Depth markers all observed @ 2 inches. Advised lettering shall be 4 inch lettering.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Skimmers observed buildup with leaves. Also, observed weirs inoperable. Advised to repair.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Maximum occupancy signs not observed.

Jun 1, 2023

Permit/Opening

Score: 962 violations

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: YesRepeat: No

Observed loose pool railings. COS- repaired

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

Observed no universal NO Diving symbol on deck. Advised to obtain