Re-inspection
3093 COBB PKWY NW KENNESAW, GA 30152-6541
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Re-inspection
Routine
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
No dial tone on emergency phone; cannot connect to dispatch. C/A: Phone must be operational and accessible.
Regulation: 511-3-5-.18(10)(a) - (a) a light, strong pole not less than twelve feet long including body hook.
Observed lack of shepherd's hook. C/A: Shepherd's hook must be present and easily accessible.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Left flow meter stuck at bottom. C/A: Must be in appropriate range.
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
Observed expired CPO certificate posted. C/A: Certificate must be current and readily available.
Re-inspection
Re-inspection
Regulation: .17((1)(c) - proper disinfectant level
Observed chlorine at 13.5ppm.
CA: Chlorine shall be between 2-10ppm.
Permit/Opening
Regulation: .17((1)(c) - proper disinfectant level
Observed Chlorine at 16ppm.
CA: Chlorine shall be between 2-10ppm.