ATLANTA, Cobb County

WILDWOOD RIDGE APARTMENTS - LARGE

1000 SHADOWOOD PKWY SE ATLANTA, GA 30339-2322

Pool
Latest score
100
Apr 20, 2026
City
ATLANTA
County
Cobb
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 20, 2026

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jul 31, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jul 17, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 14, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Apr 3, 2024

Routine

Score: 833 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone not operational. Could not dial out 911. CA: An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine at 0 ppm. CA: Free Chlorine shall be maintained between 2-10 ppm.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: YesRepeat: No

(LIGHT) observed pool underwater light out of the sidewall of the pool. CA: Place pool light securely in sidewall. COS: Light was placed back

Aug 24, 2023

Routine

Score: 1000 violations