ATLANTA, Cobb County

OVERTON RISE APARTMENTS - POOL

3695 CUMBERLAND BLVD ATLANTA, GA 30339-3112

Pool
Latest score
100
Sep 8, 2025
City
ATLANTA
County
Cobb
Inspections
9

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Sep 8, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jul 30, 2025

Re-inspection

Score: 851 violation

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

observed nonoperational emergency phone

May 6, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Apr 30, 2025

Routine

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

An operational emergency phone is needed at the pool.

May 7, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 7, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Aug 31, 2023

Re-inspection

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

The flow meter was observed not moving; CA: Adjust the flow meter.

Aug 30, 2023

Routine

Score: 794 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Chlorine observed at 0 ppm; CA: Chlorine must be between 3 and 10ppm.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH at 8.0; CA: pH must be between 7.2 and 7.8

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Water level observed below the skimmer; CA: Fill pool with water so that it will reach the skimmer

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Tighten handrails near 4ft depth marker

Jun 27, 2023

Routine

Score: 981 violation

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

The "No Lifeguard on Duty, Supervise Children Closely is needed at the pool.