2055 BARRETT LAKES BLVD NW KENNESAW, GA 30144-3196
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Re-inspection
Routine
Regulation: .17((1)(c) - proper disinfectant level
Observed chlorine at 0 ppm. Ensure chlorine is between 2 and 10 ppm.
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
Ensure CPO certificate is posted in pump room.
Routine
Re-inspection
Routine
Chlorine observed at 1.4ppm. CA: 2-10ppm Cl required.
Chemical feeder unable to maintain proper Cl levels. CA: Repair.
Weirs missing from skimmers. CA: Replace.
Permit/Opening
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Flowmeter reads 40 gpm which is under the minimum flow rate needed for an adequate turnover.
CA: Flow meter shall meet the requirements of design flow rate.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Observed no weirs in skimmers.
CA: Each skimmer shall have a functioning weir.