Sep 12, 2025
Re-inspection
3995 FREY RD KENNESAW, GA 30144
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Re-inspection
Routine
pH observed at less than 7, maintain between 7.2-7.8
skimmers not pulling
Permit/Opening
Re-inspection
Routine
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
skimmers not pulling/ missing weirs
Permit/Opening
Re-inspection
Re-inspection
Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin
Chlorine level was 14 ppm. CA: Chlorine must be maintained at 2-10 ppm.
pH was at 7.0 which is tool low. CA: pH must be maintained at 7.2-7.8.
Re-inspection
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
pH was observed at 8.0 or above. CA: pH must be maintained at 7.2-7.8.
Re-inspection
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
pH was observed at 8.0 or above. CA: pH must be maintained at 7.2-7.8.
Permit/Opening
Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
Observed gates at Frey Road and by pump room are not self closing and latching properly. CA: Facility to use alternative securement for pool gates until gate closures are repaired. Pedestrian access gates shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self latching device is located less than fifty-four inches from the bottom of the gate, 1. The release mechanism shall be located on the pool side of the gate at least three inches below the top of the gate and 2. Any openings in the gate or barrier located within eighteen inches of the release mechanism shall be less than one-half inch. 3. Mechanisms controlled by an access card reader, key entry device or keypad shall be located on the outside of the access gate.
Regulation: .17((1)(c) - proper disinfectant level
Chlorine level was 12 ppm. CA: Chlorine must be maintained from 2-10 ppm.
Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch
Observed there is no line attached to the life buoy. CA:A minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inches or a similar flotation device which is U.S. Coast Guard approved.
Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
No record of pool water testing. CA: Pool must be tested 2X daily and results recorded.
Skimmers do no appear to be operating properly. No draw was observed. CA: Maintain proper operation of the skimmers
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
Observed there was no operator training certificate on site. CA: The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority.