Permit/Opening
6 - proper disinfectant level
Regulation: .17((1)(c) - proper disinfectant level
chlorine observed at 20++ppm
C/A: maintain between 2-10ppm
6 - proper disinfectant level
Regulation: .17((1)(c) - proper disinfectant level
chlorine observed at 20++ppm
C/A: maintain between 2-10ppm
7 - ph between 7.2 and 7.8
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed pH less that 7.0; solution was bright yellow
C/A: pH shall be maintained between 7.2 and 7.8
8 - chemical feeder operational and approved
Regulation: 511-3-5-.16(1) - (1) disinfectant equipment and chemical feeders, such as flow-through chemical feeders, electrolytic chemical generators, mechanical chemical feeders, chemical feed pumps, and automated controllers shall comply with the requirements of nsf standard 5
Chemical feeder for pump #2 in dis-repair
C/A: Disinfectant equipment and chemical feeders, such as flow-through chemical feeders, electrolytic chemical generators, mechanical chemical feeders, chemical feed pumps, and automated controllers shall comply with the requirements of NSF Standard 50.
9 - filter: approved, maintained and operating
Regulation: 511-3-5-.08(1)(a) - (a) filters shall be listed per nsf standard 50 with the specific maximum flow rates per surface area based on media used.
Filter labeled #2 in disrepair
C/A: Filters shall be listed per NSF Standard 50 with the specific maximum flow rates per surface area based on media used.
10 - pump: approved, maintained and operating
Regulation: 511-3-5-.09(1) - (1) sizing. a pump and motor shall be provided for circulation of the pool and spa water. performance of all pumps shall meet or exceed the conditions of flow required for filtering and cleaning (if applicable) the filters against the total dynamic h
Observed pump labeled #2 in disrepair and not operating
C/A: A pump and motor shall be provided for circulation of the pool and spa water. Performance of all pumps shall meet or exceed the conditions of flow required for filtering and cleaning (if applicable) the filters against the total dynamic head developed by the complete system. Where applicable pumps shall comply with the NSF International Standard 50 or Underwriters Laboratories (UL) Standard 1081.
37 - other violations of the chapter
Observed the pump room door unsecured and crack at the bottom of the pool