Jul 16, 2025
Routine
6 - proper disinfectant level
chlorine observed at 1ppm, maintain between 2-10ppm
7 - ph between 7.2 and 7.8
pH observed below 7, maintain between 7.2-7.8
2055 S PARK PL SE ATLANTA, GA 30339-2014
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Routine
chlorine observed at 1ppm, maintain between 2-10ppm
pH observed below 7, maintain between 7.2-7.8
Routine
Regulation: 511-3-5-.11(4)(f) - (f) makeup water shall be supplied through an air gap or other approved backflow prevention device.
WATER LEVELS OBSERVED TOO LOW
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
NO CPO OBSERVED FOR FACILITY
Routine
Routine
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
CLEAN/REPLACE FLOW METERS
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
MAINTAIN SKIMMERS OPERATIONAL; MAINTAIN WEIRS IN SKIMMERS