MARIETTA, Cobb County

WYNFORD CHASE HOA - POOL

1289 WYNFORD COLONY MARIETTA, GA 30064

Pool
Latest score
95
May 8, 2026
City
MARIETTA
County
Cobb
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 8, 2026

Re-inspection

Score: 951 violation

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed flow rate (175gpm) unable to maintain 6-hour turnover rate. C/A: Increase flow rate to at least 235gpm to maintain turnover rate.

May 6, 2026

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed pool phone inoperable. C/A: repair pool phone.

Jun 26, 2025

Routine

Score: 981 violation

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

observed front right grab rail unattached. CA: Fix

Apr 29, 2025

Permit/Opening

Score: 912 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed stuck flowmeter-140gpm. C/A: Repair flowmeter- ensure flowrate of 236gpm.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: Yes

Observed several skimmers missing weirs. C/A: Provide weir for each skimmer.

Aug 6, 2024

Routine

Score: 961 violation

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed skimmers missing weirs. C/A: Provide weir for each skimmer.

Apr 25, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.