May 26, 2026
Re-inspection
4877 BROWN LEAF DR POWDER SPRINGS, GA 30127
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Re-inspection
Permit/Opening
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Emergency phone/911 phone not able to connect to 911 or emergency services. C/A: Fix emergency phone to reach 911.
Routine
Permit/Opening
Regulation: 511-3-5-.10(7) - (7) the vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current iampo sps 4- special use suction fitting for swimming pools, spas and hot tubs.
Vacuum line not covered/cover broke. CA: Vacuum line shall be protected and covered. CPO will get new cap
Re-inspection
Permit/Opening
Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin
Cl at 15ppm. C/A 2-10ppm
Regulation: 511-3-5-.23(5)(h) - (h) absence of required lifesaving equipment on the deck or an emergency phone;
Life ring should be US Coast Guard.