May 7, 2026
Permit/Opening
22 - signs: peak occupancy/pool/spa/signs legible and in clearview
Observed missing hours sign. Must be posted in public view.
2938 MOUNTAIN TRCE ROSWELL, GA 30075
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Observed missing hours sign. Must be posted in public view.
Routine
Regulation: 511-3-5-.18(2) - (2) rope and float line. a rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of
Float line not attached and in position.
Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
No hours or peak occupancy signs. Both signs must be displayed publicly.
Permit/Opening
Routine
Permit/Opening