ATLANTA, DeKalb County

RAMSGATE CONDOMINIUMS

2825 NORTHEAST EXPY ATLANTA, GA 30345

Pool
Latest score
95
Jun 2, 2026
City
ATLANTA
County
DeKalb
Inspections
11

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 2, 2026

Routine

Score: 951 violation

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: Yes

Only being recorded once daily instead of twice.

Apr 23, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 25, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 16, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 25, 2024

Routine

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5): All pools shall be kept free from sediment, dirt, or debris by frequently brushing and vacuuming the bottom and sidewalls. Observed staining and debris at the bottom of the pool.

Jun 27, 2024

Routine

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

13-190(A) - Equipment shall obtain the minimum of one turnover every 6 hours. Observed flowmeter reading to be 50 GPM, should be at least 86 GPM.

May 31, 2024

Routine

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

13-190(A) - Equipment shall obtain the minimum of one turnover every 6 hours 86 GPM. Observed flowmeter reading to be 80 GPM.

Apr 29, 2024

Permit/Opening

Score: 923 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

13-190(A) - Equipment shall obtain the minium of one turnover every 6 hours (~86 GPM). Observed flowmeter reading to be ~35 GPM

16 - pool deck: maintained, unobstructed and clean

2 ptsCorrected: NoRepeat: Yes

13-188(h)(3) Pool deck in very poor repair with rough surface and several large cracks that can be a tripping hazard. Please repair pool deck soon or pool permit may be withheld.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: Yes

13-201(k) No diaper changing table in bathroom.

Sep 5, 2023

Routine

Score: 863 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(A)(7) - ADEQUATELY SIZED FLOW METER SHALL BE INSTALLED TO ACCURATELY INDICATE THE CIRCULATION RATE. OBSERVED BROKEN FLOW METER

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(C)(4) - POOL WATER SHALL BE TESTED FOR DISINFECTANT AND PH AT LEAST 2 TIMES EACH DAY. OBSERVED ON LOGBOOK POOL WAS NOT BEING TESTED AT LEAST TWICE DAILY

13 - float line in position

4 ptsCorrected: YesRepeat: No

13-202(L) - TIGHTLY STRETCHED FLOAT LINE SHALL BE INSTALLED ACROSS POOL ALONG SLOPE-BREAK IN POOLS WHERE DEPTHS EXCEED 5'. OBSERVED FLOAT LINE NOT IN POSITION

Aug 1, 2023

Routine

Score: 902 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(A) - EQUIPMENT SHALL OBTAIN THE MINIMUM REQUIRED ONE TURNOVER EVERY 6 HOURS (~90 GPM). OBSERVED FLOWMETER READING ~60 GPM

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c)(4) The pool water shall be tested for the disinfectant level and pH at least 2 times a day, including prior to opening and during peak bathing loads

Jun 13, 2023

Routine

Score: 902 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(A) Equipment shall be operated continuously on a 24-hour basis to obtain the minimum required number of one turnover every 6 hours. Flowmeter was not working.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c)(4) The pool water shall be tested for the disinfectant level and pH at least 2 times a day, including prior to opening and during peak bathing loads