May 22, 2026
Permit/Opening
1296 MORELAND AVE SE ATLANTA, GA 30316
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
511-3-5-.18(10)(c),13-202(g): An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby. Observed the emergency phone dialing and not connecting to 911. Advised CPO to get the emergency phone serviced soon.
Routine
Permit/Opening
Permit/Opening
Permit/Opening
13-202(h) By the emergency phone, there should be a sign with the health department number, certified pool operator, and the manager. Sign not present.
13-189(c)(1) Chlorination levels shall be between 3 ppm - 10 ppm. Pool chlorine tested at 1.96 ppm.
13-189(c)(1) pH levels shall be between 7.2-7.8. Tested water observed at 8.6 pH.
13-197(a) Chlorinator not installed. Missing CCH Elite chlorine feeder.
13-202(d) Due to pool length, 2 sets of ring buoy and shepherd's hook are required.
6 Hour turnover rate not achieved. 6 HR= 127 gpm on flow meter.
13-197(k) Equipment room cross ventilation not achieved. Fresh air must come from top of the room. Louver installed in bottom of room.
13-202(i) Emergency action plan not complete. Plan has information referring to life guards and campers. Plan can only contain information and procedures that will be actually be done.
13-201(b) Foot baths on shower are prohibited. Need to disable or remove footbath.
13-201(c)(4) Liquid soap for showers not observed. Need dispensers for each.
13-187(c) Need to have a place to post inspection, cpo certificate, and permit.
13-189(c)(1) First aid kit not displayed in pool area.