ATLANTA, DeKalb County

HEIGHTS AT CHAMBLEE

3028 CHAMBLEE TUCKER RD ATLANTA, GA 30341

Pool
Latest score
91
Jun 24, 2025
City
ATLANTA
County
DeKalb
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 24, 2025

Routine

Score: 912 violations

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-202(c): CPO should be able to provide a daily recordkeeping of operating information, including pH and disinfectant levels. Observed: No log book was made available.

32 - operator training certification available onsite and approved

4 ptsCorrected: NoRepeat: No

13-187(c) A copy of the pool operator's certificate shall be conspicuously displayed near the operating permit.

May 19, 2025

Permit/Opening

Score: 991 violation

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

13-187(c) The current report must be displayed for the public to see.

Jun 18, 2024

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): Pool should be operated to obtain the minimum 6 turnovers per day. Observed: flow meter was not working at all.

Jun 13, 2024

Permit/Opening

Score: 802 violations

4 - water clarity: main drains clearly visible

15 ptsCorrected: NoRepeat: No

13-189(c)(6): The water should be such clarity that the main drains at the deepest point are clearly visible from the deck. Observed: Main drains are barely visible, water cloudy.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-202(c): CPO should be able to provide a daily recordkeeping of operating information, including pH and disinfectant levels. Observed: No log book was made available.

Jun 4, 2024

Permit/Opening

Score: 737 violations

4 - water clarity: main drains clearly visible

15 ptsCorrected: NoRepeat: No

13-189(c)(6): The water should be such clarity that the main drains at the deepest point are clearly visible from the deck. Observed: Main drains are barely visible, water cloudy.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): Chlorine should be maintained at between 3 ppm and 10 ppm. Observed: Chlorine test read above 17 ppm.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1): Pool should maintain a pH level between 7.2 and 7.8. Observed: First test read 8.3 and second test read 8.6.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): Pool should be operated to obtain the minimum 6 turnovers per day. Observed: flow meter read 60, should read between 200 and 210.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): An adequately sized flowmeter should be installed on the return line. Observed: required flow rate is above the measurements shown on the meter.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-184(e)(5): Imminent health hazard exists if the sanitary facilities are not maintained. Observed: Toilet in men's restroom does not work. 13-201(k): At all times, soap, toilet paper, and paper towels must be available. Observed: Neither bathroom had soap available.

31 - dressing showers: clean, maintained, hot and cold water available

1 ptsCorrected: NoRepeat: No

13-2019(c)(4): One shower with water between 70 degrees F and 104 degrees F should be provided for both men and women. Observed: Neither shower had hot water.