Brookhaven, DeKalb County

CHANTILLY STATION CONDOMINIUMS

1538 CHANTILLY DR ATLANTA, GA 30324

Pool
Latest score
94
May 21, 2026
City
Brookhaven
County
DeKalb
Inspections
9

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 21, 2026

Permit/Opening

Score: 942 violations

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: Yes

13-189(c)(4) pool water should be tested for chlorine and pH 2x daily; observed daily log to have water testing once a day or less- CPO notified HOA member to increase recordkeeping times

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-198(b): Ventilation required in the equipment room; observed fan in room but fan was not operational, CPO was informed to repair 13-188(h)(9):minimum of 1 covered and lined trash receptacle shall be provided within the pool area; observed unlined trash receptacle on pool deck

Jun 27, 2025

Re-inspection

Score: 793 violations

6 - proper disinfectant level

15 ptsCorrected: YesRepeat: No

13-189(c)(1): The free-chlorine residual shall be maintained at 3-10 ppm at all times. Observed free-chlorine residual at 2.52 ppm. *Imminent health hazard corrected on site to 3.06ppm.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c)(4): The pool water shall be tested for chlorine and pH at least 2x/day. Observed logs with testing 2x/week.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-188(h)(9): A minimum of 1 covered and lined trash receptacle shall be provided within the pool area. Observed unlined trash receptacle outside of the pool area. Note: Unlined trash receptacle observed full of water and mosquito larvae.

Jun 25, 2025

Routine

Score: 812 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The free-chlorine residual shall be maintained at 3-10 ppm at all times. Observed free-chlorine residual at 1.42 ppm. *Imminent health hazard. Pool closed.

13 - float line in position

4 ptsCorrected: NoRepeat: No

13-202(1): Tightly stretched float line shall be installed where depths exceed 5 FT. Additionally, a 4-inch non-slip tile must be installed directly beneath the entire length of the float line. Observed broken float line on pool deck. Non-slip tile also not present. *Imminent health hazard. Pool closed.

May 21, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 24, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 31, 2024

Permit/Opening

Score: 981 violation

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: Yes

13-202(m): Lettering shall be a minimum of 3/4 inches high unless stated otherwise. No signs had "No Solo Bathing" in 2-inch-high letters.

May 28, 2024

Permit/Opening

Score: 884 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): The equipment shall be operated continuously. Observed that the flowmeter was not working.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

13-188(d)(2): Pools where depths are 5 feet or less shall have permanent "No Diving" in minimum 2-inch black letters. The "No Diving" markers were not 2 inches high.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

13-202(m): Lettering shall be a minimum of 3/4 inches high unless stated otherwise. No signs had "No Solo Bathing" in 2-inch-high letters.

24 - piping identified and marked

1 ptsCorrected: NoRepeat: No

13-191(a): Water flow direction shall be indicated on exposed piping in filter room. No direction flow present.

Aug 8, 2023

Routine

Score: 961 violation

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1) Depth markers (black letters and numbers), should be a t least 4 inches. Observed lettering on depth markers less than 4 inches.

May 25, 2023

Permit/Opening

Score: 981 violation

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.

2 ptsCorrected: NoRepeat: No

Pool rail in disrepair. Must repair immediately .