Brookhaven, DeKalb County

IVY PLACE APARTMENTS

3028 CLAIRMONT RD ATLANTA, GA 30329

Pool
Latest score
60
May 29, 2026
City
Brookhaven
County
DeKalb
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 29, 2026

Permit/Opening

Score: 6014 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: Yes

13-202(g) An operable, hard-wired, weatherproof telephone, with direct 911 access or capability installed in a conspicuous location shall be readily available at all times within the pool enclosure. Observed: phone was able to ring but does not connect to 911

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) the free chlorine shall be maintained at a concentration of no less than 3.0 ppm, observed level was 1.81.

8 - chemical feeder operational and approved

15 ptsCorrected: NoRepeat: No

13-197(g) no disinfectant added by hand as the sole or primary method of adding disinfectant. Observed: large amounts of shock present on the deck, when the skimmer was opened, shock was present from when the maintenance man had added it the day before

11 - appropriate lifesaving equipment present

15 ptsCorrected: NoRepeat: No

13-202(d) each pool shall be provided with a coast guard approved lifesaving ring firmly attached to throwing rope. Ring was in good condition, but rope was broken and frayed. Rope was replaced by maintenance man on site

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) equipment shall be ran to ensure 1 turnover every 6 hours, current flow: 42 GPM, required flow: 56 GPM

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c)(4) pool water shall be tested for the disinfectant level and pH at least 2 times per day, water is currently tested once per week

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1) permanent "no diving" markers shall be located next to depth markers. Currently, the no diving markers are not next to the depth markers. Told to fix by next pool season

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-196(a) each skimmer shall be maintained in a clean condition. Large amounts of debris and shock found in skimmer

20 - return inlets maintained

4 ptsCorrected: NoRepeat: No

13-190(a) return inlets shall function and be maintained, there is currently one inlet missing

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

13-206(f) sign must state no food allowed within 5 feet of the pool and no spitting, no spouting, no blowing nose, or bodily excretions

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(k) each pool shall be supplied with a kept supplied first aid kit, observed that most of the items in the kit are expired

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-198(a) the equipment room shall adequately lighted, the light currently does not work

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-188(a) pool surfaces shall have no cracks or joints, there are currently 3 missing tiles

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5) pools shall be kept free from sediment, dirt, or debris

Jul 3, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 20, 2025

Permit/Opening

Score: 852 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

13-202(g) An operable, hard-wired, weatherproof telephone, with direct 911 access or capability installed in a conspicuous location shall be readily available at all times within the pool enclosure. *Observed 911 phone didn't work, It rang but no one didn't answer.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) Free chlorine must be a minimum of 3ppm to a maximum of 10ppm *Observed Free Chlorine at 2.59.

Jul 16, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 1, 2024

Permit/Opening

Score: 851 violation

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

13-202(a)(2)Entry into the pool area shall be at the shallow end of the pool through a self-closing, self-latching gate or door that has a positive-latching mechanism mounted at least 45" above the ground surface directly below the gate. Entrance gate must be able to self-close when opened 4" or more as measured from the gate latch to the latching mechanism.