Brookhaven, DeKalb County

DOUBLE TREE BY HILTON ATLANTA PERIMETER

4386 CHAMBLEE DUNWOODY RD BROOKHAVEN, GA 30341

Pool
Latest score
95
May 12, 2026
City
Brookhaven
County
DeKalb
Inspections
10

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 12, 2026

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

Observed low turnover rate of 60gpm (46,000 gal pool should have a minimum of 127gpm turnover rate).

13-190(a): The equipment shall be operated continuously on a twenty four hour basis to obtain the minimum required number of of four turnovers per day.

Aug 7, 2025

Re-inspection

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

Observed low turnover rate of 60gpm (46,000 gal pool should have a minimum of 127gpm turnover rate).

13-190(a): The equipment shall be operated continuously on a twenty four hour basis to obtain the minimum required number of of four turnovers per day.

Aug 4, 2025

Routine

Score: 784 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

Observed available hard-wired, weatherproof phone; however, it did not ring.

CA: 13-202(g) An operable, hard-wired, weatherproof telephone, with direct 911 access or capability installed in a conspicuous location shall be readily available at all times within the pool enclosure.

Discussed with CPO to fix the phone so it is operable as soon as possible.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

Observed high pH levels of 8.6

CA: 13-189(c)(1): The pool shall be maintained in an alkaline condition at all times with the pH between 7.2 and 7.8.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

Observed low turnover rate of 60gpm (46,000 gal pool should have a minimum of 127gpm turnover rate).

13-190(a): The equipment shall be operated continuously on a twenty four hour basis to obtain the minimum required number of of four turnovers per day. Flow meter read 60.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

Observed one ladder with unsecured right handrail (very wobbly and is coming out of the anchor).

CA: 13-184(e)(5) All steps shall have handrails anchored in the bottom step and extended over the coping and anchored in the deck.

Discussed with CPO to have it fixed as soon as possible. Until then the pool will be closed.

May 27, 2025

Re-inspection

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

Observed low turnover rate of 60gpm (46,000 gal pool should have a minimum of 127gpm turnover rate).

13-190(a): The equipment shall be operated continuously on a twenty four hour basis to obtain the minimum required number of of four turnovers per day. Flow meter read 60.

May 21, 2025

Permit/Opening

Score: 765 violations

4 - water clarity: main drains clearly visible

15 ptsCorrected: NoRepeat: No

Observed cloudy water in the pool around the main drain area. Therefore, main drains were not clearly visible.

13-189(c)(6): At all times when a pool is in use, the water shall be of such clarity that the main drains on the bottom of the pool at the deepest point are clearly visible from the deck. The viewer shall be able to clearly distinguish the type, shape and number of openings of the main drain grates.

Discussed with CPO to allow the pool to run a cycle so the water can clear.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed FCL to measure low at 2.87ppm.

13-189(c)(1): Where stabilizing agents are used, a free-chlorine residual shall be maintained at a concentration of no less than three parts per million (3ppm) at all times.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

Observed high pH levels measuring at 7.9

13-189(c)(1): The pool shall be maintained in an alkaline condition at all times with the pH between 7.2 and 7.8.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

Observed low turnover rate of 60gpm (46,000 gal pool should have a minimum of 127gpm turnover rate).

13-190(a): The equipment shall be operated continuously on a twenty four hour basis to obtain the minimum required number of of four turnovers per day. Flow meter read 60.

13 - float line in position

4 ptsCorrected: NoRepeat: No

Observed NO stretched float line with plastic floats installed across the pool along the slope-break where the depths exceeds 5 feet.

13-202(l): A tightly stretched polypropylene or nylon rope or float line with plastic floats shall be installed across the pool along the slope-break in pools where the depths exceed five feet (5’).

CPO has the float line rope ordered. Will have it ready for re-inspection.

Jul 30, 2024

Routine

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) The equipment shall be operated continuously on a twenty four hour basis to obtain the minimum required number of of four turnovers per day. Flow meter read 60.

Jun 3, 2024

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-205(b)(1) Turnover every 6 hours Observation: flow meter should read 127 gpm. Observed flow meter reading at 50 gpm.

May 28, 2024

Permit/Opening

Score: 756 violations

3 - compliant drain covers secure, present and no cracks

15 ptsCorrected: NoRepeat: No

13-190(a)(4): Main drain openings must be covered by an approved, secured grating. Main drains were not visible and therefore could not be checked.

4 - water clarity: main drains clearly visible

15 ptsCorrected: NoRepeat: No

13-189(c)(6): The viewer should be able to clearly distinguish the type, shape, and number of openings on the main drain grates or covers. The water was not clear enough to see the bottom of the pool.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type

5 ptsCorrected: NoRepeat: Yes

13-205(b)(1) Turnover every 6 hours Observation: flow meter should read 127 gpm. Observed flow meter reading at 60 gpm.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

13-184(e)(5): Unsecured handrails considered an imminent health hazard. Handrail opposite entry way not secured into the ground.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

13-202(m): Rules must contain at a minimum the 12 statements provided by Dekalb County. Pool signs did not include "No Solo Bathing"

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(i): Each pool should have a displayed and approved emergency action plan. A template was provided and should be filled out by next scheduled permitting inspection.

Jul 17, 2023

Routine

Score: 912 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

13-205(b)(1) Turnover every 6 hours Observation: flow meter should read 97 gpm. Observed flow meter reading at 60 gpm.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

13-188(d)(1) Depth markers indicated in feet and inches, metric allowed only if accompanied by feet and inches. Observation: tiles in feet and metric. Must be corrected by end of pool season. If not corrected by permit inspection of 2024 season, permit will not be issued.

May 16, 2023

Permit/Opening

Score: 912 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-205(b)(1) Turnover every 6 hours Observation: flow meter should read 97 gpm. Observed flow meter reading at 55 gpm.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1) Depth markers indicated in feet and inches, metric allowed only if accompanied by feet and inches. Observation: tiles in feet and metric. Must be corrected by end of pool season. If not corrected by permit inspection of 2024 season, permit will not be issued.