Chamblee, DeKalb County

ACV CHAMBLEE, LLC DBA 10 PERIMETER PARK

10 PERIMETER PARK DR ATLANTA, GA 30341

Pool
Latest score
69
Jun 12, 2026
City
Chamblee
County
DeKalb
Inspections
12

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 12, 2026

Routine

Score: 697 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

13-202(g): An operable, hard-wired, weatherproof telephone, with direct 911 access or capability installed in a conspicuous location shall be readily available at all times within the pool enclosure. No cellphones! Emergency phone inoperable.

6 - proper disinfectant level

15 ptsCorrected: YesRepeat: No

Chlorine initially read 0.88 ppm, so I called the CPO who sent over a pool tech to correct it. Final reading read 3.75 ppm.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): The equipment shall be operated continuously on a 24 hour basis to obtain the minimum required number of 4 turnovers per day, or one turnover every 6 hours for standard pools. Flow meter read 50 gpm instead of required 116.66 gpm.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-202(c): Each pool operator shall maintain and make available for inspection onsite upon request a daily record of operating information, together with other data as may be required for each pool relative to operation of the pool. No pool log available on site upon request.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Permanent, slip-resistant, easily-readable depth markers at least 4 inches high; black letters and numbers on a white background indicated in feet and inches. Depth markers on deck read 3 1/2 ft.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k): At all times, an adequate supply of liquid soap, toilet paper, and paper towels shall be provided and stored in appropriate dispensers conveniently accessible to users. No paper towels or liquid soap in women's bathroom.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Emergency, pool operator, and health dept. numbers posted by phone. No CPO or health dept. numbers listed.

Apr 30, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 6, 2025

Routine

Score: 991 violation

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

13-201(b) if no bathhouse is required, a shower with tempered water with a temperature range maintained between 70F and 104F shall be provided at each approved entrance into the pool area. Observed: Both shower decks have only cold water

Jun 18, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 28, 2025

Permit/Opening

Score: 784 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

the emergency phone would not dial out

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

the turnover rate was low. for this pool, a six-hour turnover rate is required, but at the time of inspection, the turnover rate was 7 hours

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

the handicapped equipment was broken in the restroom, which can cause a hazard to handicapped swimmers

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

There was no emergency action plan available on site

Aug 14, 2024

Routine

Score: 961 violation

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Depth markers must read in feet and inches. Observed: 3 1/2 ft marker must read 3 ft 6 in.

Aug 9, 2024

Re-inspection

Score: 922 violations

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Depth markers must read in feet and inches. Observed: 3 1/2 ft marker must read 3 ft 6 in.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2): Cyanuric acid levels must not exceed 100ppm. Observed: Test read 114ppm.

Aug 7, 2024

Routine

Score: 903 violations

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Depth markers must read in feet and inches. Observed: 3 1/2 ft marker must read 3 ft 6 in.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2): Cyanuric acid levels must not exceed 100ppm. Observed: Test read 130ppm.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: YesRepeat: No

13-184(e)(5): Unsecured handrails considered an imminent health hazard. Observed: Ladder not secured in the ground. Corrected on site.

Jun 5, 2024

Routine

Score: 922 violations

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Depth markers must be indicated in feet and inches. Observed: On pool deck, multiple depth markers read 3 1/2 feet. Should instead read 3 ft 6 in.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: YesRepeat: No

13-189(c)(2): Cyanuric acid levels must not exceed 100 ppm. Observed: Initial cyanuric test read 105, CPO drained some water and the following test read 93.

May 2, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 13, 2023

Routine

Score: 803 violations

6 - proper disinfectant level

15 ptsCorrected: YesRepeat: No

13-189(c)(1) - Chlorine must maintain a measurement of 3ppm-10ppm. Water tested at .84. COS, second reading gave 3.56.

6 - proper disinfectant level

15 ptsCorrected: YesRepeat: No

13-189(c)(1) - Chlorine must maintain a measurement of 3ppm-10ppm. Water tested at .84. COS, second reading gave 3.56.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7)- Adequately sized flow meter must be installed and operational. Flow meter was not working for the second return line.

Jun 16, 2023

Permit/Opening

Score: 942 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a)- Equipment shall be operated continuously on a 24 hour basis to obtain minimum turnover rate. Flow meter read below minimum, at 75.

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

13-201 (b) - Deck shower must be maintained, deck shower does not work.