May 22, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 15, 2025

Routine

Score: 942 violations

32 - operator training certification available onsite and approved

4 ptsCorrected: NoRepeat: No

13-187(c): a copy of the pool operator's certificate shall be conspicuously displayed near the operating permit; at time of inspection, the certificate was not displayed (though the CPO's information was posted).

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

13-202(m): safety rules and regulations shall be easily readable and posted in the pool area; at time of inspection, it was observed that different signs have different bather loads (178 and 302, while the state DHD system lists the bather load as 186)

Jun 6, 2025

Permit/Opening

Score: 981 violation

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

13-188(f): all steps shall have handrails anchored in the bottom step; observed at time of inspection that two of the three grab rails are slightly loose (not to any extreme extent and not warranting a failing permitting at this time) and may need to be more tightly secured in the future

May 23, 2025

Permit/Opening

Score: 794 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

13-202(g) Emergency phone not operational.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) Turnover rate insufficient. For a 34,500 gal pool with a 6 hr turnover rate, the flowmeter should be 96 gpm minimum. The flowmeter was observed to be 90 gpm.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(i) No written emergency action plan available. Template provided to CPO.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-197(k) Pool chemicals must be stored up off the floor in the pump room.