Decatur, DeKalb County

ARLO

245 E TRINITY PL DECATUR, GA 30030

Pool
Latest score
100
Apr 20, 2026
City
Decatur
County
DeKalb
Inspections
10

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 20, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Apr 30, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 19, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jul 18, 2024

Routine

Score: 852 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The free chlorine levels shall be between 3ppm and 10ppm for outdoor pools: Chlorine was observed at 10.2ppm, 10.55ppm, and 11.55ppm at inspection after three tests.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The pool shall be in an alkaline condition at all times. The pH level shall be between 7.2-7.8 at all times. pH reading was 6.9 at inspection.

Jun 12, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jun 4, 2024

Re-inspection

Score: 852 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The free chlorine levels shall be between 3ppm and 10ppm for outdoor pools: Chlorine was observed at 15.31 at inspection.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: Yes

13-189(c)(1): The pool shall be in an alkaline condition at all times. The pH level shall be between 7.2-7.8 at all times. pH reading was 7.9 at inspection.

Jun 3, 2024

Routine

Score: 715 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The pH level shall be between 7.2-7.8 at all times: pH reading was 6.4 at inspection.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): the equipment shall be operated continuously on a twenty-four (24) hour basis to obtain minimum required turnovers. Required turnovers not met.

32 - operator training certification available onsite and approved

4 ptsCorrected: YesRepeat: No

13-187(c): a copy of the pool operator's certificate shall be conspicuously displayed near operating permit. Certificate was not posted at time of inspection but COS.

35 - operator facility inspections performed; written documentation

4 ptsCorrected: NoRepeat: No

13-187(c): The current inspection report shall be conspicuously displayed near operating permit. Certificate was not posted at time of inspection but COS.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(c)(i): Each pool shall have a proper test kit for their chemical readings: Observed that the chemicals in the test kit were expired.

Apr 15, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 19, 2023

Permit/Opening

Score: 991 violation

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k) A minimum of 1 diaper changing station for babies shall be provided in each men's and women's bathroom.

Jun 15, 2023

Routine

Score: 805 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

13-202(g) Emergency phone not working at time of visit. An operable phone must be installed and be readily available at all times within pool area.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-1989(c)(1): The free chlorine levels shall be between 3ppm and 10ppm for outdoor pools:chlorine was 0.21 at inspection.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The pH level shall be between 7.2-7.8 at all times: pH reading was 6.6 at inspection.

11 - appropriate lifesaving equipment present

15 ptsCorrected: NoRepeat: No

13-202(d) Along with a ring buoy, a shepherds hook is also required within the pool area, attached to a non-telescoping pole with a minimum of 14 feet and made with a blunt end.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a) An adequately size flow meter shall be installed on the return line to indicate circulation rate in gallons per minute. Observed flow meter was not functional at time of inspection.