Decatur, DeKalb County

CORTLAND ON PONCE

220 PONCE DE LEON PL DECATUR, GA 30030

Pool
Latest score
100
Jun 9, 2026
City
Decatur
County
DeKalb
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 9, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 7, 2026

Permit/Opening

Score: 755 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed free chlorine residual at greater than 12 ppm.

13-189(c)(1) a free-chlorine residual shall be maintained at a concentration of no less than three parts per million (3ppm) at all times. Free chlorine (stabilized or unstabilized) shall not exceed ten parts per million (10ppm) except when super-chlorinating or shocking the pool.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

Observation: Observed pool water pH level testing at 6.6.

Violation: 13-189(c)(1), the pool water shall be maintained in an alkaline condition at all times with a pH level between 7.2 and 7.8. Observed pH level was below the required minimum range.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

Observation: Observed two out three weirs missing

13-196(a)(4) Each skimmer shall have a properly designed and operating weir or other departmentally approved means of providing effective skimming

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2) Cyanuric acid levels shall not exceed 100ppm.

Observed cyanuric level at 110ppm

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

Observation: Observed handrails not securely fastened and loose at the pool area.

Violation: 13-184(e)(5), handrails shall be properly installed and maintained in a secure condition. Unsecured handrails are considered an imminent health hazard due to the potential safety risk to patrons.

Corrective Action: Immediately repair and tighten all loose handrails to ensure they are securely fastened and safe for use. Maintain handrails in good repair and routinely inspect for stability to prevent safety hazards.

Aug 18, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 2, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 29, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jul 25, 2024

Routine

Score: 863 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): The equipment shall be operated continuously on a twenty-four (24) hour basis to obtain the minimum required turnover rate. Could not get an accurate reading on flow meter.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): An adequately sized flow meter shall be installed on the return line to accurately indicate the circulation in GPM. Flow meter was not operating.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2): Cyanuric acid levels shall not exceed 100ppm. Pool was observed at 132ppm.

Jun 13, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 11, 2023

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(i) Observed no EAP plan in place.