DORAVILLE, DeKalb County

EMBRY CROSSING CONDOMINIUMS

3551 OLD CHAMBLEE-TUCKER ROAD, APT. E DORAVILLE, GA 30340

Pool
Latest score
61
Jun 10, 2026
City
DORAVILLE
County
DeKalb
Inspections
3

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 10, 2026

Permit/Opening

Score: 6112 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Entry gate does not self-latch to close or open.

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Access gate does not self-latch.

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Free chlorine measured at 1.08 ppm.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

No daily record keeping.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Turnover rate measured at 45gpm.

13 - float line in position

Regulation: 511-3-5-.18(2) - (2) rope and float line. a rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of

4 ptsCorrected: NoRepeat: No

Pool reaches a depth of over 5ft, and no float line was in position.

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

No CPO for pool at all. No certification available onsite.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

No signs in view.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

No first aid kit available.

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

Piping was unmarked with no arrows.

31 - dressing showers: clean, maintained, hot and cold water available

1 ptsCorrected: NoRepeat: No

No hot water available.

34 - inspection report placed in public view

Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.

1 ptsCorrected: NoRepeat: No

Blank inspection report onsite.

Jul 3, 2025

Permit/Opening

Score: 952 violations

13 - float line in position

4 ptsCorrected: NoRepeat: No

13-202(l) Tightly stretched float line shall be installed across pool along slope-break in pools where depths exceed 5'.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No
  1. Other Violations of the chapter Bathroom had lots of leaves on the floor, looked like it hadn't been swept in a while

Jul 31, 2023

Routine

Score: 037 violations

1 - barrier: pool enclosed/fencing in compliance

15 ptsCorrected: NoRepeat: No

n/a

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

n/a

11 - appropriate lifesaving equipment present

15 ptsCorrected: NoRepeat: No

n/a

3 - compliant drain covers secure, present and no cracks

15 ptsCorrected: NoRepeat: No

n/a

4 - water clarity: main drains clearly visible

15 ptsCorrected: NoRepeat: No

n/a

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

n/a

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

n/a

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

n/a

8 - chemical feeder operational and approved

15 ptsCorrected: NoRepeat: No

n/a

9 - filter: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

n/a

10 - pump: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

n/a

14 - vacuum line protected

5 ptsCorrected: NoRepeat: No

n/a

18 - combined chlorine level 0.4 ppm or less

5 ptsCorrected: NoRepeat: No

n/a

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

n/a

23 - automated controller operational; pumps interlocked

5 ptsCorrected: NoRepeat: No

n/a

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

n/a

33 - lifeguard training certification available onsite

5 ptsCorrected: NoRepeat: No

n/a

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

n/a

13 - float line in position

4 ptsCorrected: NoRepeat: No

n/a

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

n/a

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

n/a

20 - return inlets maintained

4 ptsCorrected: NoRepeat: No

n/a

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

n/a

26 - gauge(s) in proper location; sight glass installed

4 ptsCorrected: NoRepeat: No

n/a

27 - supplemental disinfection c uv system, c ozone system

4 ptsCorrected: NoRepeat: No

n/a

32 - operator training certification available onsite and approved

4 ptsCorrected: NoRepeat: No

n/a

35 - operator facility inspections performed; written documentation

4 ptsCorrected: NoRepeat: No

n/a

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

n/a

16 - pool deck: maintained, unobstructed and clean

2 ptsCorrected: NoRepeat: No

n/a

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

n/a

25 - pump strainer: basket cleanable

2 ptsCorrected: NoRepeat: No

n/a

24 - piping identified and marked

1 ptsCorrected: NoRepeat: No

n/a

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

n/a

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

n/a

31 - dressing showers: clean, maintained, hot and cold water available

1 ptsCorrected: NoRepeat: No

n/a

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

n/a

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

n/a