Druid Hills, DeKalb County

HIGHLAND SQUARE APARTMENTS

1400 BRIARCLIFF RD NE ATLANTA, GA 30306

Pool
Latest score
99
Jun 15, 2026
City
Druid Hills
County
DeKalb
Inspections
10

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 15, 2026

Re-inspection

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

13-187(c): A copy of the pool operator's certificate shall be conspicuously displayed. Observed wallet-sized CPO certificate on display. Please display original, full-sized, certificate so the information listed is readable.

Jun 10, 2026

Routine

Score: 913 violations

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: Yes

13-190(a): All circulation components shall function properly in a clean condition. Observed 2/3 skimmer baskets filled with debris & pool toys. CPO corrected on-site and skimmers were freed of debris.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: Yes

13-189(c)(2): Cyanuric acid levels shall not exceed 100 ppm. Conducted cyanuric acid tests two separate times and observed readings of 122 and 106 ppm. Cyanuric acid levels must be restored before pool can re-open.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-187(c): A copy of the pool operator's certificate shall be conspicuously displayed. Observed CPO certificate displayed in appropriate location, but had difficulty reading the information displayed, as the certificate was printed on a small sheet of paper (approx. smaller than the size of a standard business card).

May 8, 2026

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-198(b): Ventilation of fresh make-up air must be provided for all equipment rooms. Observed ventilation system not functional.

May 4, 2026

Permit/Opening

Score: 812 violations

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

13-202(a)(2): Entry to pool area shall be through self latching and self closing gates. Observed one entrance gate not self-latching.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2): Cyanuric acid levels shall not exceed 100ppm. Observed cyanuric acid level of 231.

Jun 26, 2025

Re-inspection

Score: 952 violations

17 - skimmers/gutters maintained and operable

4 ptsCorrected: YesRepeat: No

13-190(a): All circulation components shall function properly and be maintained in clean condition. Observed skimmers full of leaves. Corrected on site. No imminent health hazard present.

37 - other violations of the chapter

1 ptsCorrected: YesRepeat: No

13-189(b): Approved backflow prevention must be provided on all water lines. Observed hose submerged in pool supplying water. Corrected on site. CPO informed there must be an air gap.

Jun 23, 2025

Routine

Score: 904 violations

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c)(4): The pool water shall be tested for pH and chlorine 2x/day. Observed logs with testing 2x/week.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2): Cyanuric acid levels shall not exceed 100ppm. Observed levels at 131ppm.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(c)(3) 1 lavatory with tempered water with a temperature range of 70 F to 104 F shall be provided for each 100 men and women. Observed water pressure drastically decrease when turning on hot water. No imminent health hazard observed in restrooms.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k): An adequate supply of soap, paper towels, and toilet paper shall be provided in restrooms. Observed no paper towels in women's restroom.

May 6, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 7, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 31, 2024

Permit/Opening

Score: 884 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) Pool equipment shall obtain a minimum of one turnover every 6 hours. Flow meter showed 0 GPM (inoperable).

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2): Cyanuric acid levels shall not exceed 100ppm. Observed: 118ppm.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

13-184(e)(5): Unsecured handrails considered an imminent health hazard-safety hazard. One ladder is completely secured while the other ladder is not screwed into the pool wall.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(c)(3) 1 lavatory with tempered water with a temperature range of 70 F to 104 F shall be provided for each 100 men and women. Observed no hot water for sinks.

Jun 26, 2023

Routine

Score: 912 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7) An adequately sized flow meter shall be installed on the return line to accurately indicate the circulation rate in gallons per minute. Flow meter not working at time of inspection.

32 - operator training certification available onsite and approved

4 ptsCorrected: NoRepeat: No

13-187(c) A copy of the pool operator's certificate shall be conspicuously displayed near the operating permit. Certificate identified expired August 2022. Operator assured me training was already completed and he's awaiting certificate.