Dunwoody, DeKalb County

GEORGETOWN AT PERIMETER WALK CONDOMINIUMS

211 PERIMETER WALK DUNWOODY, GA 30338

Pool
Latest score
85
Jun 1, 2026
City
Dunwoody
County
DeKalb
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 1, 2026

Routine

Score: 854 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-205(b)(1): Equipment shall be operated continuously on a 24 hour basis to obtain minimum required number of 1 turnover every 6 hours for standard pool. Turnover rate as shown by flow meter was 75 gpm instead of required 86.11 gpm.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c)(4): Pool water shall be tested for disinfectant level and pH at least 2 times each day or as often as necessary if circumstances warrant, including prior to opening and during peak bathing loads. Observed that pool log only had 1 recorded test every few days for the month of May.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

13-188(d)(1): Permanent, slip-resistant easily-readable depth markers at least 4 inches high; black letters and numbers on a white background indicated in feet and inches when applicable. Depth markers indicate 3 1/2 ft instead of 3 feet 6 inches. Depth markers on deck have tan background instead of white.

31 - dressing showers: clean, maintained, hot and cold water available

1 ptsCorrected: NoRepeat: Yes

13-201(c)(4): 1 shower with tempered water with a temperature range between 70 degrees Farenheit and 104 degrees Farenheit shall be provided for each 100 men or women. No hot water for men or women's showers.

Apr 23, 2026

Permit/Opening

Score: 933 violations

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

13-188(d)(1): Markers shall read in ft and inches.

Observation: Markers are in fractions. "3 1/2 ft".

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.

2 ptsCorrected: NoRepeat: No

13-188(h)(3) Pool deck obstructed with pallets of patio furniture. Please remove pallets prior to pool opening!

31 - dressing showers: clean, maintained, hot and cold water available

1 ptsCorrected: NoRepeat: No

13-201(c)(4): Showers with tempered water with a temperature range of 70 to 104 degrees fahrenheit shall be provided for each 100 men or women. Observed that showers in restrooms did not have access to hot water.

Jul 3, 2025

Permit/Opening

Score: 961 violation

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Markers shall read in ft and inches.

Observation: Markers are in fractions. "3 1/2 ft".

Jun 27, 2024

Re-inspection

Score: 854 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

13-190(a): Equipment shall be operated continuously on a twenty four hour basis to obtain minimum number of 4 required turnovers per day. Observed that pool flow meter was at 45 gpm but for pool of this size turnover rate required was 122 gpm.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: Yes

13-201(c): Operator shall maintain a daily record of operating information, together with other data, including pH, disinfectant levels, maintenance procedures, with other such relevant data. Observed that the daily pool records log indicated that pool was not being tested twice daily.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

13-188(d)(1): Black letters and numbers on a white background indicated in feet and inches when applicable. Observed that depth markers using metric in half feet instead of inches as well as depth markers using colored background.

31 - dressing showers: clean, maintained, hot and cold water available

1 ptsCorrected: NoRepeat: Yes

13-201(c)(4): 1 shower with tempered water with a temperature range of 70 to 104 degrees fahrenheit shall be provided for each 100 men or women. Observed that showers in restrooms did not have access to hot water.

Jun 26, 2024

Routine

Score: 687 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): Outside pools only, A free chlorine residual shall be maintained at 3 ppm at all times and shall not exceed 10 ppm. Observed that the free chlorine residual for pool was tested at 2.08 ppm.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

13-190(a): Equipment shall be operated continuously on a twenty four hour basis to obtain minimum number of 4 required turnovers per day. Observed that pool flow meter was at 45 gpm but for pool of this size turnover rate required was 122 gpm.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-201(c): Operator shall maintain a daily record of operating information, together with other data, including pH, disinfectant levels, maintenance procedures, with other such relevant data. Observed that the daily pool log could not be located during inspection.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

13-188(d)(1): Depth markers indicated in feet and inches when applicable. Observed that depth markers using metric in half feet instead of inches.

24 - piping identified and marked

1 ptsCorrected: NoRepeat: No

13-191(a): All valves and piping in the equipment room shall be clearly labels and water flow direction shall be indicated. Observed that pump room did not have label for water flow, valves, and piping.

31 - dressing showers: clean, maintained, hot and cold water available

1 ptsCorrected: NoRepeat: No

13-201(c)(4): 1 shower with tempered water with a temperature range of 70 to 104 degrees fahrenheit shall be provided for each 100 men or women. Observed that showers in restrooms did not have access to hot water.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-198(a): Entry door for equipment room shall open to the exterior and shall be kept locked except for servicing. Observed that pool equipment room was not locked during the inspection.

Apr 26, 2024

Permit/Opening

Score: 903 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

observed turnover rate at 60GPM. The turnover rate of a 35,000 gallon pool on 6 hour turnover rate is 97GPM.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(a)(1) Permanent, slip resistant easily readable depth markers of 4 inches high; black letters and numbers on a white background indicated in feet and inches. Observed 1/2 markers and "FT" in less than 4inches

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k): At all times bathrooms shall have an adequate supply of liquid soap, toilet paper, and paper towels. Observed no toilet paper or paper towels in bathrooms. Men's restroom toilet paper holder in disrepair. Advised to clean bathrooms.

Jul 25, 2023

Re-inspection

Score: 845 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): The pool shall be maintained at 1 turnover every 6 hours. For a pool of 44,000g, the turnover rate must be greater than 122 gpm. Observed turnover rate of 70 gpm.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c)(4): The pool water shall be tested for disinfectant and pH at least 2x daily. Observed empty testing logs.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Depth markers indicated in both feet and inches. Observed depth markers listed in 1/2 and 1/3 ft.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k): At all times bathrooms shall have an adequate supply of liquid soap, toilet paper, and paper towels. Observed both bathrooms without paper towels.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-197(k): All pools shall have safe, dedicated storage for chemicals. Observed chemicals on the floor of the pump room. Must be moved to pallet/shelf.

Jul 20, 2023

Routine

Score: 697 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The free chlorine residual in all parts of the pool shall be maintained at a concentration between 3-10 ppm at all times. Observed free chlorine at 10.5 ppm.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The pool shall be maintained in an alkaline condition at all times with a pH level between 7.2-7.8. Observed pH at 8.0.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): The equipment shall be operated continuously to maintain the minimum rate of 1 turnover every 6 hours. For a pool of 44,000 g, the turnover rate should be greater than 122 gpm. Observed turnover rate of 80 gpm.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c)(4): The pool water shall be tested for disinfectant and pH at least 2 times daily. Observed empty testing logs.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Depth markers indicated in both feet and inches. Observed depth markers listed in 1/2 and 1/3 ft.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-021(k): At all times bathrooms shall have an adequate supply of liquid soap, toilet paper, and paper towels. Observed both bathrooms without paper towels.

31 - dressing showers: clean, maintained, hot and cold water available

1 ptsCorrected: NoRepeat: No

13-201(c)(4): 1 shower with tempered water for every 100 men or women. Observed both showers were dirty. Men's shower did not have water.