Dunwoody, DeKalb County

CAMDEN DUNWOODY APARTMENTS

10 PEACHFORD CIR DUNWOODY, GA 30338

Pool
Latest score
98
May 27, 2026
City
Dunwoody
County
DeKalb
Inspections
11

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 27, 2026

Permit/Opening

Score: 983 violations

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

Deck shower did not meet temperature requirements.

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

Didn't meet the temperature range requirement.

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

No current inspection.

Sep 5, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Aug 21, 2025

Re-inspection

Score: 843 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) Free chlorine residual shall be maintained at a concentration of no less than three parts per million (3ppm) at all times. Free chlorine shall not exceed ten parts per million (10ppm). Chlorine levels were 11.87.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1) The pool shall be maintained in an alkaline condition at all times with a pH level between 7.2-7.8. pH levels were 7.1 at the time of the inspection.

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

13-201(b) If not bathhouse is required a shower with tempered water with a temperature range maintained between 70 F and 104F shall be provided at each approved entrance into the pool. Deck shower was not working.

Aug 12, 2025

Routine

Score: 794 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) A free chlorine residual shall be maintained at a concentration of no less than three parts per million shall not exceed ten parts per million. Chlorine levels for second test were 41.74 for first test chlorine levels were 27.5

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2) Cyanuric acid levels shall not exceed 100ppm. Cyanuric acid was at 190 at time of testing.

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

13-201(b) A shower with tempered water with a temperature range maintained between 70 F and 104 F shall be provided. Deck shower was not working.

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

13-187(c) The current inspection report shall be displayed in a conspicuous place where it is easy readable by the public at all times upon entry into the pool. No current inspection was displayed.

May 23, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 18, 2024

Routine

Score: 843 violations

6 - proper disinfectant level

15 ptsCorrected: YesRepeat: No

Observed chlorine disinfectant level to be corrected on site.

Readings: 2.18 6.33

7 - ph between 7.2 and 7.8

15 ptsCorrected: YesRepeat: No

Observed pH level to be corrected on site.

Readings: 7.9 7.8

30 - deck/rinse shower maintained

1 ptsCorrected: YesRepeat: No

Observed deck rinse shower to be corrected on site and running hot and cold water.

May 24, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 23, 2024

Permit/Opening

Score: 852 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): Code says disinfectant must be between 3.0-10.0ppm -First Reading: 0.64 -Second Reading: 0.8

8 - chemical feeder operational and approved

15 ptsCorrected: NoRepeat: No

13-197(a): The water in each pool shall be continuously chemically treated with an approved disinfecting agent, with associated, approved equipment, whereby the residual can be easily measured by simple and accurate field tests. The free chlorine did not meet the required level, and when the chlorinator was turned up, no change was observed.

Aug 3, 2023

Routine

Score: 737 violations

6 - proper disinfectant level

15 ptsCorrected: YesRepeat: No

13-189(c)(1): Code says disinfectant must be between 3.0-10.0ppm -First Reading: 0.35 -Second Reading: 8.31 -COS

7 - ph between 7.2 and 7.8

15 ptsCorrected: YesRepeat: Yes

13-189(c)(1): Code says pH should be between 7.2-7.8 -First Reading: 7.1 -Second Reading: 7.4 -COS

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-205(b)(1): Code says there must be 1 turnover every 6 hours -Turnover needed: 125gpm -Turnover observed: 115gpm

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: Yes

13-196(a)(4): Code says skimmers should have operable weirs -Observed no weirs

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: YesRepeat: Yes

13-201(k): Code says bathrooms must be stocked with toilet paper and paper towel -Observed neither in women's room -COS

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: Yes

13-201(b): Code says there must be a deck shower that is operable -Observed shower to be under construction

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

13-187(c): Code says current inspection must be in public view -Observed old inspection

Jun 28, 2023

Routine

Score: 745 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: YesRepeat: No

13-189(c)(1): Code says pH should be between 7.2-7.8 -First Reading: 7.1 -Second Reading: 7.4 -COS

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): Code says return line must have an adequately sized flow meter -Observed flow meter to be too small and stuck -Needs to be able to read 125gpm

17 - skimmers/gutters maintained and operable

4 ptsCorrected: YesRepeat: No

13-196(a)(4): Code says skimmers should have operable weirs -Observed no weirs -COS

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: YesRepeat: No

13-201(k): Code says bathrooms must be fully stocked -Observed no paper towels in bathrooms -COS

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

13-201(b): Code says there must be a deck shower that is operable -Deck shower was not operable

May 25, 2023

Permit/Opening

Score: 912 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): Code says flow rate must be 1 turnover every 6 hours and should have an appropriate flow rate. -Required flow: 125 -Observed flow: 80

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-196(a)(4): Code says each skimmer must have an operable weir

  • Observed no weirs in any skimmers