Dunwoody, DeKalb County

BELL PERIMETER CENTER 1000

70 PERIMETER CENTER E ATLANTA, GA 30346

Pool
Latest score
100
May 23, 2025
City
Dunwoody
County
DeKalb
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 23, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 22, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Aug 1, 2024

Routine

Score: 784 violations

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

13-202(a)(2) Entry into the pool area shall be at the shallow end of the pool through a self-closing, self-latching gate or door that has a positive-latching mechanism mounted at least 45” above the ground surface directly below the gate.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2)Cyanuric Acid levels shall not exceed 100ppm

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

13-184(e)(5)Unsecured handrails considered an imminent health /safety hazard

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

#37 Missing weirs in skimmers

May 23, 2024

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

Observed the flow rate at 90gpm. The equipment shall be operated continuously on a 24- hour basis to obtain the minimum required of 4 turnover per day, or one turnover every 6 hours. For a 37,000 gallon pool, the minimum flow rate is 103 gpm.

May 13, 2024

Permit/Opening

Score: 803 violations

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

Observed magnetic strip not properly functioning to maintain gate and door closed. 13-202(a)(2) Entry into the pool area shall be at the shallow end of the pool through a self-closing, self-latching gate or door that has a positive-latching mechanism mounted at least 45” above the ground surface directly below the gate.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) A free chlorine residual in all parts of the pool shall be maintained between 3-10ppm. Observed chlorine test at .33ppm.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

An adequately sized flow meter shall be installed on the return line to accurately indicate the circulation rate. Observed flow meter not functioning.

Jun 12, 2023

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a)The equipment shall be operated continuously to obtain the minimum of one turnover every six hours. Flow reading was low at time of inspection.

May 26, 2023

Permit/Opening

Score: 718 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) A free chlorine residual of no less than 3ppm shall be maintained at all times. This was observed to be less at time of inspection.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1) Alkalinity was higher than the specified pH range in code which between 7.2-7.8

8 - chemical feeder operational and approved

15 ptsCorrected: NoRepeat: No

13-189(a) The water in pool shall be continually chemically treated with an approved disinfecting agent, with associated approved equipment, whereby the residual can easily be measured. The chlorine residual reading was low and chlorinator was not working at time of inspection.

9 - filter: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

13-193(a) Pressure gauges damaged at inspection, each sand filter must have adequate working pressure gauges.

11 - appropriate lifesaving equipment present

15 ptsCorrected: NoRepeat: No

13-202(d) Each pool shall be equipped with a shepherds hook attached to a non-telescoping pole. The hook was detachable at time of inspection.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-205(a)(1) A minimum of one turnover every six hours is required for pools.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a) A minimum of one turn over is required every six hours for pools.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-196(a)(4) Each skimmer shall have a properly designed and operating weir, three of four weirs were missing.