Dunwoody, DeKalb County

EMBASSY SUITES ATLANTA PERIMETER CENTER SPA

1030 CROWN POINTE PKWY DUNWOODY, GA 30338

Pool
Latest score
84
Feb 18, 2026
City
Dunwoody
County
DeKalb
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Feb 18, 2026

Re-inspection

Score: 843 violations

4 - water clarity: main drains clearly visible

15 ptsCorrected: YesRepeat: No

13-189(c)(6): at all times, the water shall be of such clarity that the main drains are clearly visible from the deck. Observed that the main drains were not clearly visible from the deck. Corrected on-site by CPO, who turned on feature pump, which restored water clarity after a few minutes.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

13-189(c)(1): an approved test kit shall be used by the CPO to test chemical levels. Observed that CPO's testing kit still is not complete with up-to-date, non-expired testing chemicals.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

13-190(a)(8): pools equipped with heaters shall have a thermometer designed for use in the pool and which can be viewed by bathers Observed that spa thermometer was not working.

Feb 9, 2026

Routine

Score: 844 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): Bromine levels must be maintained between 3ppm - 8ppm. Observed bromine reading of 9.3ppm.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1): the pool shall be maintained in an alkaline condition at all times with a pH level between 7.2 - 7.8. Observed pH level at 7.1.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(c)(1): an approved test kit shall be used by the CPO to test chemical levels. Observed that chemicals in CPO's testing kit were expired.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-190(a)(8): pools equipped with heaters shall have a thermometer designed for use in the pool and which can be viewed by bathers. Observed that spa thermometer did not work.

Jul 25, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 9, 2024

Routine

Score: 851 violation

6 - proper disinfectant level

15 ptsCorrected: YesRepeat: No

13-189(c)(1): Bromine levels must be maintained between 3ppm-8ppm. OBSERVATION: initially it was 13.4. After adjustment, it went to 8.0.

Jun 28, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Oct 26, 2023

Routine

Score: 834 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): Bromine levels must be maintained between 3-8 ppm. It was observed and tested at 1.9ppm. COS to 5.9ppm.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The pool shall maintain an alkaline condition at all times with a pH between 7.2-7.8. It was tested and observed at 7.1. COS to 7.6

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

13-187(c): the current inspection must be placed in a conspicuous place where it is easily readable. It was not posted anywhere in the pool area.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5): all pools shall be kept free from sediment, dirt, or debris by frequent brushing and vacuuming. The surface of the pool need to be brushed due to staining and there is sand at the bottom of the pool.

Jun 30, 2023

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jun 21, 2023

Permit/Opening

Score: 775 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): Bromine levels must be maintained between 3-8 ppm. Observation: Initially bromine was 0.9. After adjustment it went to 11.6.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1): The pool shall maintain an alkaline condition at all times with a pH between 7.2-7.8. Observation: pH was 6.6. After adjustment it went to 7.0.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a): equipment shall be operated continuously on a 24 hour basis to obtain minimum required turn over of 1/2 an hour. Observation: Flow meter is not showing a reading. CPO will replace it. Flow metr must be 1.5x of turnover rate (30 gpm). Max value should be 45 gpm.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

13-202(m): Rules must contain at a minimum the 12 statements in the pool code. Observation: No food or drink allowed sign is missing.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-184(h): permit holder or designee shall have a procedure called "recommended Procedures for Managing Fecal Accidents or Contamination With Vomitous or Blood in Swimming Pool". Observation: No such procedure found.