North Decatur, DeKalb County

PANGBORN SWIM CLUB (POOL)

2785 MILLWOOD CT DECATUR, GA 30033

Pool
Latest score
95
May 19, 2026
City
North Decatur
County
DeKalb
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 19, 2026

Permit/Opening

Score: 952 violations

26 - gauge(s) in proper location; sight glass installed

4 ptsCorrected: NoRepeat: No

13-193(a): Sand filters shall have an adequately sized in-line sight glass on the backwash line. Observed no sight glass.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k): An adequate supply of liquid body soap shall be provided to bathers at all times. Observed no liquid body soap in either restroom - instructed board member to get soap before opening. No IHH at this time.

May 12, 2026

Permit/Opening

Score: 769 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

13-202(g): An operable, hard wired phone with 911 access will be readily available at all times. Observed emergency phone not functional and kept in lifeguard room. Advised CPO and board member that a sign stating phones location is required.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): Free chlorine residual must be maintained at 3-10ppm at all times. Observed FCL of 10.38ppm.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1): pool shall be maintained at a pH of 7.2-7.8 at all times. Observed pH of 8.

11 - appropriate lifesaving equipment present

15 ptsCorrected: NoRepeat: No

13-202(d): Pool shall be provided with a coast guard approved lifesaving ring attached to a rope handle. Observed rope handle broken and fraying.

11 - appropriate lifesaving equipment present

15 ptsCorrected: NoRepeat: No

13-202(d): Additional sets of lifesaving equipment for pools longer than 50ft. are required. Observed only 1 set of lifesaving equipment.

26 - gauge(s) in proper location; sight glass installed

4 ptsCorrected: NoRepeat: No

13-193(a): an adequately sized in-line sight glass on the backwash line is required. Observed no sight glass on backwash line.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

13-184(e)(5): Unsecured hand rails considered an imminent health hazard. Observed hand rails on both sets of steps loose.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

13-202(m): Minimum 12 required statements must be posted and easily readable. Observed several required statements missing, provided CPO with required statements list.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k): An adequate supply of liquid soap shall be provided to bathers at all times. Observed no liquid hand or body soap in either restroom.

May 7, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 2, 2023

Routine

Score: 817 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: YesRepeat: No

13-190(a): all circulation equipment shall function properly. Obs: CPO fixed flow meter.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: YesRepeat: No

13-196(a)(4): each skimmer shall have properly designed and operating weir. Obs: CPO added weirs to 5/7 skimmers.

26 - gauge(s) in proper location; sight glass installed

4 ptsCorrected: NoRepeat: No

13-193(a): an adequately sized in-line backwash sight glass on the backwash line. Obs: No sight glass on backwash line.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: YesRepeat: No

13-184(e)(5): Unsecured handrails imminent health hazard. Obs: CPO tightened handrail in the deep end.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

13-202(m): Safety rules and regulations shall contain minimum 12 statements. Obs: Sign is missing "telephone is located____", "no animals", "no running" and bather load & hours of operation. Provided CPO with copy of rules.

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

13-201(b): A shower with tempered water with range of 70-104 degrees shall be provided. Obs: No hot water in deck rinse.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5): All pools shall be kept free of sediment, dirt, or debris by frequent brushing/vacuuming of bottom & sidewalls. Obs: Visible leaves/pine twigs at bottom of pool-- mainly in deeper end.

13-198(b): Enclosure must be ventilated with outside air by a chlorine-resistant exhaust fan with vents located a max of 4 inches above floor level, equipped with automatic louvers to achieve cross-flow ventilation. Obs: No exhaust fan present.

May 18, 2023

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

May 16, 2023

Permit/Opening

Score: 825 violations

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

13-202(a)(2) entrance gate must be able to self close when open 4" or more as measured from the gate latch to the latching mechanism. Observation: entry gate is not self closing at 4".

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c) fcl shall be maintained at 3-10ppm at all times Observation: 1st reading 1 second reading 1.5

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1) pool pH must be maintained between 7.2-7.8 at all times. pH observed at 7.1 second reading 7.4

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

13-202(m) Safety rules and regulations shall contain minimum statements and correct sizing. Provided page 42 of code for pools

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202 (h) Emergency, pool operator, and health department numbers must be posted at the emergency phone.